New Holland 520305-04: Right Drawtube Back Voltage below normal, or shorted to low source
Issue description
The fault code indicates an issue with the voltage in the Right Drawtube Back circuit, which is either below normal levels or shorted to a low source. This may affect the proper operation of the component associated with this circuit.
Check the cause
Right Drawtube Back Voltage levels
Circuit connections for the Right Drawtube Back
Potential shorting in the Right Drawtube Back circuit
Repair steps
Check
The voltage levels of the Right Drawtube Back circuit using a multimeter.
Inspect
The wiring and connections related to the Right Drawtube Back for signs of damage, wear, or shorting.
Test
The circuit for continuity and insulation integrity to identify any shorting to a low source.
Parts you might need