520313-06

New Holland 520313-06: PRV1 (Wing Frame) Current above normal, or shorted to ground

Issue description

The fault code indicates that PRV1 (Wing Frame) is experiencing current above normal levels or is shorted to ground. This may result in improper operation or damage to the affected circuit.

Check the cause

  1. PRV1 (Wing Frame) wiring

  2. PRV1 (Wing Frame) connections

  3. PRV1 (Wing Frame) functionality

Repair steps

  1. Inspect

    Inspect the wiring and connections related to PRV1 (Wing Frame) for damage, wear, or loose contacts.

  2. Test

    Test PRV1 (Wing Frame) for proper operation and current levels using appropriate diagnostic tools.

  3. Repair or replace

    If damage or malfunction is found, repair or replace PRV1 (Wing Frame) as needed.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other New Holland codes