New Holland 6010 – MFD/Diff Lock: Low Voltage Supply in 12VS1 Circuit
Issue description
The 12VS1 voltage supply is low, which may indicate a problem with the power source or the circuit supplying power to this component. This issue could affect the proper operation of the system connected to this voltage supply.
Check the cause
Voltage supply to 12VS1
Connections in the 12VS1 circuit
Fuse associated with 12VS1 (if applicable)
Repair steps
Check the voltage supply to 12VS1
Use a multimeter to measure the voltage at the 12VS1 connection point. Ensure it meets the required specifications.
Inspect connections in the 12VS1 circuit
Check for loose, corroded, or damaged connections in the wiring associated with 12VS1.
Verify the integrity of the fuse (if applicable)
If the system includes a fuse for the 12VS1 circuit, check if it is intact. Replace if necessary.
Parts you might need
(0)Get help to fix this fault by requesting a quote