New Holland 6015: Frame Fold Solenoid Driver Power Detected When Interlock Relay Is Disabled
Issue description
The MIU detects power being supplied to the Frame Fold Solenoid driver even though the MIU Interlock Relay is disabled. This indicates an unexpected electrical condition that may affect the proper operation of the system.
Check the cause
The status of the MIU Interlock Relay
The wiring and connections to the Frame Fold Solenoid driver
The integrity of the electrical circuit supplying power to the Frame Fold Solenoid driver
Repair steps
Verify the status of the MIU Interlock Relay
Ensure the relay is properly disabled as intended by the system logic.
Inspect the wiring and connections to the Frame Fold Solenoid driver
Check for any loose, damaged, or shorted wiring that could cause unintended power flow.
Test the electrical circuit supplying power to the Frame Fold Solenoid driver
Use a multimeter to confirm that power is not present when the MIU Interlock Relay is disabled.
Parts you might need
(0)Get help to fix this fault by requesting a quote