New Holland 8011 – ARM: Battery Voltage is Too Low

Issue description

The system has detected that the battery voltage is below the acceptable level. This may affect the operation of the machine and could lead to performance issues or failure to start.

Check the cause

  1. Battery connections for corrosion or looseness

  2. Battery terminals for proper contact

  3. Battery charge level using a multimeter

  4. Alternator output if available

Repair steps

  1. Inspect

    Check the battery connections for corrosion, looseness, or damage.

  2. Test

    Measure the battery voltage using a multimeter to confirm the low voltage condition.

  3. Charge or Replace

    If the battery is low, charge it using a suitable charger. If it does not hold a charge, replace it.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other New Holland codes