9154
New Holland 9154: CAN Connection - TSC1 Message Timed Out
Issue description
The system has detected a timeout in the CAN connection related to the TSC1 message. This indicates a communication issue within the affected circuit.
Check the cause
The integrity of the CAN bus wiring
Connections at the TSC1 module
Power supply to the TSC1 module
Repair steps
Inspect
Inspect the CAN bus wiring for damage, corrosion, or loose connections.
Test
Test the connections at the TSC1 module for proper continuity and voltage.
Verify
Verify the power supply to the TSC1 module is stable and within specifications.
Parts you might need
(0)Get help to fix this fault by requesting a quote