9158
New Holland 9158: H Pattern Indicator Shorted To Ground White
Issue description
The H Pattern Indicator is experiencing a short to ground on the white wire. This fault indicates an electrical issue within the circuit associated with the H Pattern Indicator.
Check the cause
The white wire connected to the H Pattern Indicator
The H Pattern Indicator itself
Connections and wiring harness related to the H Pattern Indicator
Repair steps
Inspect
Check the white wire for any damage, fraying, or contact with ground.
Test
Use a multimeter to test for continuity between the white wire and ground.
Repair
If a short is found, repair or replace the damaged section of the white wire.
Parts you might need
(0)Get help to fix this fault by requesting a quote