9159

New Holland 9159 – UCM: Pattern Select (ISO/H) Short to Ground

Issue description

A short to ground has been detected in the Pattern Select (ISO/H) circuit. This fault indicates an electrical issue within the affected circuit, potentially causing improper operation of the component identified by this code.

Check the cause

  1. The wiring and connections related to the Pattern Select (ISO/H) circuit

  2. The integrity of the wiring insulation for signs of damage or wear

  3. Potential moisture or contamination in the circuit

Repair steps

  1. Inspect

    Inspect the wiring and connections related to the Pattern Select (ISO/H) circuit for damage, wear, or loose connections.

  2. Test

    Test the circuit for continuity and insulation resistance using a multimeter, following the service manual procedures.

  3. Clean

    Clean any areas of the circuit that show signs of moisture, dirt, or contamination.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other New Holland codes