ARM109
New Holland ARM109: 3rd Remote Hydraulic Flow Control Failure
Issue description
The system has detected a failure in the 3rd remote hydraulic flow control. This may affect the operation of the hydraulic system associated with this component.
Check the cause
The 3rd remote hydraulic flow control
The wiring and connections to the 3rd remote hydraulic flow control
The hydraulic system for leaks or blockages
Repair steps
Inspect
Inspect the 3rd remote hydraulic flow control for visible damage or wear.
Check
Check the wiring and connections to the 3rd remote hydraulic flow control for looseness, corrosion, or damage.
Test
Test the 3rd remote hydraulic flow control for proper function using the appropriate diagnostic tools.
Parts you might need
(0)Get help to fix this fault by requesting a quote