ARM39

New Holland ARM39: 2nd Remote Hydraulic Control Lever Potentiometer Failure

Issue description

The system has detected a failure in the 2nd remote hydraulic control lever potentiometer. This component is responsible for transmitting the position of the control lever to the system. A failure in this component may result in improper operation of the hydraulic system.

Check the cause

  1. The 2nd remote hydraulic control lever potentiometer

  2. Connections and wiring related to the 2nd remote hydraulic control lever potentiometer

Repair steps

  1. Inspect

    Inspect the 2nd remote hydraulic control lever potentiometer for visible damage or wear.

  2. Test

    Test the 2nd remote hydraulic control lever potentiometer for proper functionality using the appropriate diagnostic tools.

  3. Replace

    If the 2nd remote hydraulic control lever potentiometer is found to be faulty, replace it with a compatible component.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other New Holland codes