New Holland ARM79: Hitch Load Control Potentiometer Failure

Issue description

The system has detected a failure in the hitch load control potentiometer, which is responsible for monitoring and adjusting the load on the hitch. This fault may affect the proper operation of the hitch system.

Check the cause

  1. Hitch load control potentiometer

  2. Wiring connections to the hitch load control potentiometer

  3. Power supply to the hitch load control potentiometer

Repair steps

  1. Inspect

    Visually inspect the hitch load control potentiometer for signs of damage or wear.

  2. Check

    Verify the wiring connections to the hitch load control potentiometer for looseness, corrosion, or damage.

  3. Test

    Test the power supply to the hitch load control potentiometer using a multimeter to ensure it is receiving the correct voltage.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote