New Holland ARMRE 119 – Armrest Controller: Aux 4th remote valve FLOW potentiometer is failed
Issue description
The electronic controller is no longer receiving a valid signal from the dial/knob used to adjust the hydraulic flow rate for the 4th auxiliary remote valve.
Applies to these machines
20 machines- T6
- T7
- T8
- T9
- TG210
- TG230
- TG245
- TG255
- TG285
- TJ Series
- CR Series Combines
- CX Series Combines
- Magnum
- Steiger
- Puma
- Maxxum
- T7000 series
- TM series
- T4 series
- TX series combines
Check the cause
Attempt to recalibrate the armrest controls through the A-post monitor or Pro700 display by cycling the levers and dials through their full range of motion to clear a stuck or out-of-range fault
Remove the armrest cover and inspect the wiring harness leading to the 4th remote flow potentiometer for chafed wires, loose connector pins, or corrosion
On older series (like the TG series), check the active CAN bus terminators located inside the armrest for broken solder joints which can cause communication dropouts
Repair steps
Turn off the tractor and disconnect battery power
This prevents short circuits during the repair.
Remove the retaining screws on the armrest console
Lift off the top cover to access the Electronic Hydraulic Remote (EHR) control section.
Locate the specific potentiometer
Find the potentiometer for the 4th remote valve flow control.
Unplug the electrical harness connector
Carefully unplug the connector from the back of the failed potentiometer.
Remove the retaining nut or mounting clip
Remove the hardware securing the potentiometer to the armrest housing, and pull the knob/potentiometer assembly out.
Insert the new potentiometer into the housing
Secure it with the retaining nut/clip.
Reconnect the electrical harness connector
Plug the connector into the back of the new potentiometer.
Reassemble the armrest console cover
Secure the cover back onto the armrest console.
Restore battery power and perform an armrest calibration
Perform the calibration via the tractor's display to ensure the new potentiometer's minimum and maximum voltage values are learned by the Armrest Controller.
Parts you might need
(5)EHR Flow Control Knob Potentiometer / Armrest Control Unit Potentiometer
87663294Fits most modern New Holland T-Series (T6, T7, T8, T9) and Case IH equivalents
EHR Flow Control Knob Potentiometer / Armrest Control Unit Potentiometer
87755846Fits most modern New Holland T-Series (T6, T7, T8, T9) and Case IH equivalents
EHR Flow Control Knob Potentiometer / Armrest Control Unit Potentiometer
87605247Fits T7000 series, TM series (TM115-TM175), and T4 series
EHR Flow Control Knob Potentiometer / Armrest Control Unit Potentiometer
92296190Fits TJ series and older articulated tractors (Replaces 259012A1)
EHR Flow Control Knob Potentiometer / Armrest Control Unit Potentiometer
84043856Fits TX series combines
Get help to fix this fault by requesting a quote