ARMRE 18025

New Holland ARMRE 18025 – Armrest Module (ARMRE / ARU): Rear hitch slip control potentiometer - voltage too low

Issue description

The slip control potentiometer is a dial/knob used by the operator to set the desired wheel slip percentage for the rear hitch draft control system. A "voltage too low" condition indicates that the signal voltage returning from this potentiometer to the controller has dropped below the minimum acceptable threshold. This is typically caused by a faulty potentiometer, a short to ground in the wiring harness, or a disconnected plug.

Applies to these machines

  • New Holland T7 Series
  • New Holland T8 Series
  • New Holland T9 Series

Check the cause

  1. Access the tractor's H9 diagnostic menu (Switch & Sensor Test Functions) and navigate to Channel 33, which monitors the slip control potentiometer.

  2. Perform a sweep test by turning the slip control knob fully clockwise, and then fully counter-clockwise.

  3. Verify the values displayed on the screen range between 84 and 14.

  4. Perform a wiggle test by moving the wiring harness and connectors near the potentiometer while monitoring H9 Channel 33. If values jump or drop out, there is an intermittent circuit/wiring issue.

Repair steps

  1. Inspect Wiring

    Based on the diagnostic test, inspect the wiring harness leading to the slip control potentiometer inside the armrest console. Look for chafed wires shorting to a ground source or corroded connector pins.

  2. Repair Harness

    If a wiring fault is found during the wiggle test, repair the damaged section of the harness or replace the connector.

  3. Replace Potentiometer

    If the wiring is intact but the H9 Channel 33 values are out of the 84-14 range (or stuck low), the potentiometer itself has failed internally.

  4. Disassembly

    Remove the necessary trim panels on the armrest console to access the underside of the slip control knob.

  5. Swap Part

    Unplug the faulty potentiometer, remove its retaining nut/clip, and install the new potentiometer.

  6. Clear and Verify

    Turn the tractor on, clear the stored ARMRE 18025 fault code, and re-test the system for normal operation to ensure the code does not return.

Parts you might need

(1)
  • Rear Hitch Slip Control Potentiometer

    Genuine CNH Industrial parts are recommended for armrest electronics to ensure correct voltage scaling (84 to 14 range) with the ARU module. Look up in CNH parts catalog using machine's PIN/Serial Number.

Get help to fix this fault by requesting a quote