New Holland ARMRE 18028 – Armrest Control Module (ACM): EHR 5 lever position - voltage too high
Issue description
The signal voltage coming from the Electronic Hydraulic Remote (EHR) #5 lever potentiometer has exceeded the maximum acceptable threshold. If the tractor is not physically equipped with a 5th EHR lever, it indicates incorrect configuration of the ACM.
Applies to these machines
6 machines- New Holland T6 Series (T6.140 - T6.175)
- New Holland T6000 Series
- New Holland T7 Series (T7.170 - T7.270)
- New Holland T7000 Series
- New Holland T8 Series (T8.275 - T8.435)
- New Holland T9 Series
Check the cause
Verify ACM Configuration: Use the Electronic Service Tool (EST) to check Config B/b 5.3 - EHR 5 lever position. If the tractor does not have a 5th remote lever, the configuration is incorrect.
Inspect Wiring: If equipped with an EHR 5 lever, inspect the wiring harness and connectors between the EHR 5 lever potentiometer and the ACM for a short to a 5V/12V power source or an open ground circuit.
Attempt Calibration: Try to recalibrate the armrest controls through the A-post display or EST to see if the module can relearn the potentiometer's voltage range.
Test the Potentiometer: If calibration fails or the voltage remains pegged high, the potentiometer has likely failed internally.
Repair steps
Correct Configuration (If Applicable)
If the tractor lacks an EHR 5 lever, use the EST to reconfigure the ACM to match the tractor's actual hydraulic remote setup. Clear the code.
Access the Armrest
If the potentiometer is faulty, power down the tractor and disassemble the armrest console to access the underside of the EHR lever bank.
Remove the Faulty Sensor
Disconnect the electrical connector from the EHR 5 lever potentiometer/switch assembly. Unbolt or unclip the faulty potentiometer from the lever housing.
Install the New Part
Install the replacement potentiometer and reconnect the wiring harness.
Reassemble
Carefully reassemble the armrest console, ensuring no wires are pinched.
Calibrate
Turn the key on and enter the armrest calibration mode (via the A-post or EST). You must perform the lever calibration procedure so the ACM can learn the exact voltage values for the new potentiometer's neutral, extend, and retract positions.
Parts you might need
(2)Arm Rest Control Unit Potentiometer / Switch (EHR Flow Control Knob Potentiometer)
87755846Fits New Holland T6, T6000, T7, T7000, T8, and T9 series tractors.
Arm Rest Control Unit Potentiometer / Switch (EHR Flow Control Knob Potentiometer)
87660885Alternative OEM Reference. Fits New Holland T6, T6000, T7, T7000, T8, and T9 series tractors.