New Holland ARMRE 18029 – ACM: EHR 6 lever position - voltage too low
Issue description
The Armrest Control Module (ACM) is receiving a signal voltage from the 6th Electro-Hydraulic Remote (EHR) control lever potentiometer that is below the minimum expected threshold. This indicates an open circuit, a short to ground, or a failed internal potentiometer. If the tractor is not physically equipped with a 6th rear remote valve, this code indicates the ACM is incorrectly configured and looking for a sensor that does not exist.
Applies to these machines
4 machines- T6 Series
- T7 Series
- T8 Series
- T9 Series
Check the cause
Verify Machine Configuration: Count the physical remote valves on the rear of the tractor. If the machine only has 3, 4, or 5 remotes, the ACM configuration is incorrect and needs to be updated. No parts replacement is necessary.
Inspect Wiring & Connectors: If the tractor does have a 6th remote, remove the armrest console cover. Inspect the wiring harness and the electrical connector going to the #6 EHR lever for backed-out pins, corrosion, or pinched wires.
Voltage & Ground Check: Using a multimeter, verify that the lever is receiving the 5V reference signal and has a good ground from the ACM.
Potentiometer Sweep Test: Back-probe the signal wire while moving the lever back and forth. The voltage should transition smoothly. If the voltage stays near 0V or drops out entirely, the lever's internal potentiometer has failed.
Repair steps
Connect diagnostic tool
If it is a configuration issue: Connect the OEM diagnostic tool (Electronic Service Tool - EST).
Navigate to ACM settings
Navigate to the Armrest Control Module (ACM) configuration settings.
Update configuration
Update the configuration to match the actual number of installed remote valves.
Save and clear
Save the configuration, cycle the key, and clear the fault code.
Power off and disconnect battery
If the EHR Lever has failed: Power off the machine and disconnect the battery ground.
Disassemble armrest console
Disassemble the right-hand armrest console cover to access the EHR lever block.
Locate faulty lever
Locate the #6 EHR lever (levers are modular and color-coded).
Disconnect electrical connector
Disconnect the electrical connector from the faulty lever.
Remove retaining hardware
Remove the retaining hardware/clips securing the lever to the armrest assembly.
Install replacement lever
Install the replacement EHR lever and secure it.
Reassemble armrest console
Reconnect the electrical harness and reassemble the armrest console.
Reconnect battery
Reconnect the battery and power on the tractor.
Perform calibration
Perform a remote valve and armrest calibration via the tractor's display monitor (ICP) or the dealer diagnostic tool to ensure the new lever's full travel range is learned by the ACM.
Parts you might need
(6)Black Control Lever
87613726Replaced by 90493684
Black Control Lever
90493684Replaces 87613726
Ginger Control Lever
87613725Blue Control Lever
87613724Green Control Lever
87613723Joystick / Lever Assembly
90493683
Get help to fix this fault by requesting a quote