ARMRE 18035

New Holland ARMRE 18035 – Armrest Module (ARU): Front hitch position height limit potentiometer - voltage too high

Issue description

This indicates that the signal voltage returning from the potentiometer (which controls the maximum height limit for the front hitch) is exceeding the expected upper threshold. This is typically caused by a short to power in the wiring, a loss of ground, or an internal failure of the potentiometer itself.

Applies to these machines

  • T6.140
  • T6.145
  • T6.150
  • T6.155
  • T6.160
  • T6.165
  • T6.175
  • T6000 Series
  • T7.170 through T7.315
  • T7000 Series
  • T8.275 through T8.435
  • T9.390 through T9.700
  • Puma
  • Magnum
  • Steiger

Check the cause

  1. Inspect the Electronic Draft Control (EDC) knobs on the armrest for physical damage, sticking, or liquid spills, which commonly short out armrest electronics.

  2. Test the wiring harness between the Armrest Module and the height limit potentiometer. Look for a short to a 12V or 5V power source and verify that the potentiometer has a solid ground connection.

  3. Use the tractor's H-Menu (Switch & Sensor Test Functions, specifically menu H9) to check the operation of the potentiometer and voltage supplies to see if the sensor is reading out of bounds.

  4. Attempt to recalibrate the front hitch via the IntelliView display (Hitch Cal menu). If the calibration aborts or fails to read the potentiometer sweep, the component is likely dead.

Repair steps

  1. Power Down

    Turn off the tractor and disconnect the battery to prevent shorting sensitive armrest electronics.

  2. Access the EDC Panel

    Carefully pry up or unscrew the Electronic Draft Control panel on the tractor's right-hand armrest to expose the underside of the control knobs.

  3. Remove the Potentiometer

    Disconnect the electrical connector leading to the front hitch height limit potentiometer. Remove the control knob from the top, then undo the retaining nut or clips holding the potentiometer in the armrest housing.

  4. Install the New Part

    Seat the new potentiometer into the armrest, secure the retaining hardware, and reattach the control knob.

  5. Reconnect

    Plug the wiring harness back into the sensor and reassemble the armrest panel. Reconnect the battery.

  6. Recalibrate

    You must perform a hitch calibration after replacing the potentiometer so the Armrest Module can learn the new minimum and maximum voltage values of the sensor. Turn the key on, navigate to the Hitch Calibration menu on the display, and follow the on-screen prompts to set the travel limits.

Parts you might need

(3)
  • EHR Flow Control Knob Potentiometer / Arm Rest Control Unit Potentiometer

    87663294

    Primary replacement number for T6, T7, T8, T9 series EHR flow/height control potentiometers. Verify exact tractor serial number with a CNH dealer, as the specific part number can vary slightly between Auto Command (CVT) and Power Command (Powershift) armrest configurations.

  • EHR Flow Control Knob Potentiometer / Arm Rest Control Unit Potentiometer

    87755846

    Alternative/superseded part reference for the armrest control unit potentiometer. Verify exact tractor serial number with a CNH dealer.

  • EHR Flow Control Knob Potentiometer / Arm Rest Control Unit Potentiometer

    87605247

    Potentiometer used on some T7000 and T6000 series variants. Verify exact tractor serial number with a CNH dealer.

Get help to fix this fault by requesting a quote