New Holland ARMRE 18040 – Armrest Module (ARMRE): EHR 1 lever position - voltage too low
Issue description
This fault code indicates that the signal voltage from the Electronic Hitch/Hydraulic Remote (EHR) 1 lever position sensor (potentiometer) has dropped below the acceptable minimum threshold. This typically points to an open circuit, a short to ground in the sensor wiring, or a complete internal failure of the EHR 1 lever potentiometer located in the armrest.
Applies to these machines
11 machines- New Holland T6 Series
- New Holland T7 Series
- New Holland T8 Series
- New Holland T9 Series
- New Holland T6000 series
- New Holland T7.185
- New Holland T7.220
- New Holland T7.270
- New Holland T8.320
- New Holland T8.415
- New Holland TG245
Check the cause
Inspect the EHR 1 lever on the armrest for physical damage, binding, or debris that might prevent smooth operation.
Attempt to recalibrate the armrest controller and EHR levers through the A-post or IntelliView display before replacing parts.
Remove the armrest cover and inspect the wiring harness connecting the EHR 1 lever to the armrest module for pinched wires, chafing (short to ground), or loose/corroded connector pins (open circuit).
Verify that the potentiometer is receiving the standard 5V reference signal from the controller. If the reference voltage is present but the signal return is abnormally low or zero when the lever is moved, the potentiometer has failed.
Repair steps
Power Down
Turn off the tractor and disconnect the battery ground cable to prevent electrical shorts.
Access the Armrest Internals
Remove the retaining screws on the side/bottom of the right-hand armrest console and carefully lift the top cover to expose the EHR control modules.
Disconnect the Lever
Locate the EHR 1 lever assembly (usually the first lever from left to right, corresponding to remote valve 1). Unplug the electrical connector from the lever's potentiometer.
Remove the Faulty Component
Remove the mounting screws holding the EHR 1 lever/switch assembly in place and extract it from the armrest housing. (Note: On some older or specific models, the entire EHR control block may need to be replaced as a single unit if individual levers are not serviceable).
Install the New Part
Seat the new EHR lever or potentiometer into the armrest, secure it with the mounting screws, and reconnect the wiring harness.
Reassembly
Carefully reinstall the armrest cover, ensuring no wires are pinched in the process. Reconnect the battery.
Mandatory Calibration
Turn the key on and enter the tractor's calibration menu via the display monitor. Perform the armrest and EHR lever calibration procedure to allow the Armrest Module to learn the new potentiometer's minimum and maximum voltage limits.
Parts you might need
(6)Control Lever (EHR, RH Armrest)
48138533Replaced by # 90434927. Fitment: New Holland T8 series and similar.
Control Lever (EHR, RH Armrest)
90434927Replaces # 48138533. Fitment: New Holland T8 series and similar.
Control Lever (EHR, RH Armrest)
87613723Fitment: New Holland T8 series and similar.
EHR Flow Control Knob Potentiometer
87663294Fitment: New Holland T-Series (e.g., T4.XXF).
EHR Flow Control Knob Potentiometer
87755846Alternative reference for 87663294. Fitment: New Holland T-Series (e.g., T4.XXF).
Electronic Armrest Lift/EHR Control Unit (Complete Assembly)
87648539Fitment: New Holland T6000 Series (T6030, etc.) Range and Power Command tractors.
Get help to fix this fault by requesting a quote