ARMRE 18046

New Holland ARMRE 18046 – Armrest Controller Module: EHR float control switch error

Issue description

Malfunction, out-of-range voltage, or resistance failure in the float control switch/potentiometer located on one of the EHR control levers on the tractor's armrest.

Applies to these machines

  • T7 Series (T7.170, T7.185, T7.220, T7.235, T7.250, T7.260, T7.270)
  • T8 Series (T8.xxx)
  • T9 Series
  • T7000 Series

Check the cause

  1. Check the lever potentiometer resistance: Disconnect the EHR control unit connector. While operating the EHR lever from 'extend' to 'float', measure resistance (Pin 6 to Pin 1 should be 100-900 Ohms; Pin 6 to Pin 2 should be 900-100 Ohms).

  2. Check for +5 Volts reference: Turn keystart ON. Measure voltage between Pin 1 and Pin 2 on the harness side (should be approximately +5 Volts).

  3. Check for open circuits or shorts: Turn keystart OFF. Check continuity between the EHR connector and the main Armrest module connectors. Check Pin 1 for any short to ground.

Repair steps

  1. Attempt Calibration

    Enter the tractor's H-Menu (H9 / Channel 55) via the instrument cluster and perform the EHR lever calibration procedure.

  2. Software Update

    If the EHR lever calibrates but the error code immediately returns, connect the Electronic Service Tool (CNH EST) to download/flash the correct level of software to the Armrest module, then repeat the calibration procedure.

  3. Replace the Component

    If the fault occurs again after calibration and software updates, or if the potentiometer failed the resistance bench-test in the diagnostic phase, remove the armrest trim and replace the faulty EHR control lever assembly.

  4. Final Calibration

    After installing the new lever, you must run the EHR lever calibration procedure again so the Armrest module learns the new potentiometer's exact voltage limits for the float detent.

Parts you might need

(6)
  • EHR Control Lever / Joystick (General)

    90493683
  • EHR Control Lever (Green)

    87613723
  • EHR Control Lever (Blue)

    87613724
  • EHR Control Lever (Ginger/Tan)

    87613725
  • EHR Control Lever (Black)

    90493684

    Replaces older # 87613726

  • Armrest EHR Control Unit / Module (Main Board)

    87524031

    Alternative # 84296089. Only replace this if the main board is diagnosed as faulty rather than the individual lever.

Get help to fix this fault by requesting a quote