ARMRE 69

New Holland ARMRE 69 – Armrest Controller: HITCH POSITION command potentiometer is failed

Issue description

The tractor's data bus has signaled that the hitch controller received a failure signal from the armrest controller regarding this specific potentiometer. This means the physical rotary potentiometer in the cab (attached to the hitch position control lever) is either sending an out-of-range signal, has an open/shorted circuit, or the controller itself has a software execution error.

Applies to these machines

  • New Holland TG210
  • New Holland TG230
  • New Holland TG255
  • New Holland TG285
  • New Holland TG305
  • New Holland T8010
  • New Holland T8020
  • New Holland T8030
  • New Holland T8040
  • New Holland T8050
  • New Holland T8 Series (T8.275 through T8.435)
  • New Holland TJ275
  • New Holland TJ325
  • New Holland TJ375
  • New Holland TJ425
  • New Holland TJ450
  • New Holland TJ500

Check the cause

  1. Inspect the connector ends at the potentiometer and the armrest controller for damaged, bent, or dislocated pins.

  2. Verify potentiometer resistance by disconnecting it and measuring across the outer cavities (Cavity 1 to Cavity 3); it should read between 900 and 1100 ohms.

  3. Perform a sweep test by measuring resistance between the signal pin (Cavity 2) and ground pin (Cavity 3). Resistance should change smoothly from 0 to approximately 1000 ohms (or 4 kohms) over a 120-degree clockwise rotation without dropouts.

  4. Check controller voltage at the potentiometer connector. Cavity 1 (high side) should receive 8 volts of regulated power from the controller, and Cavity 3 is the ground.

  5. Check the wiring harness between the hitch/armrest controller and the potentiometer for high resistance or an open circuit.

Repair steps

  1. Power down

    Power down the tractor and disconnect the battery ground.

  2. Remove

    Remove the access panels on the right-hand console / armrest control panel to expose the underside of the hitch control levers.

  3. Disconnect

    Disconnect the wiring harness connector from the hitch position command potentiometer.

  4. Remove

    Remove the retaining nut (typically a 3/8-32 nut) and pull the control lever/knob assembly to free the potentiometer from the console bracket.

  5. Install

    Install the new potentiometer, ensuring the alignment tab seats correctly in the bracket so the 120-degree sweep matches the physical travel of the lever.

  6. Reinstall

    Reinstall the retaining nut and the control lever.

  7. Reconnect

    Reconnect the wiring harness and reassemble the right-hand console.

  8. Power on

    Power on the tractor and clear the fault codes.

  9. Calibrate

    Perform a hitch controller calibration after replacing the potentiometer. If the calibration is not completed successfully, the system will throw a secondary fault code, ARM 9021.

Parts you might need

(3)
  • Potentiometer, 1000 Ohm, Hitch Position

    256304A2

    Fits the right-hand console for New Holland TG series (TG210, TG230, TG255, TG285) and equivalent Case IH models.

  • Retaining Nut

    A39888
  • Rotary Potentiometer

    326282A1

    Alternative/Superseded Part used in various T8 and TG series cab interior control panels.

Get help to fix this fault by requesting a quote

Browse other New Holland codes