New Holland ARMRE 89 – Armrest Controller: Aux 1st remote valve FLOW potentiometer is failed
Issue description
The rotary knob/potentiometer on the armrest—which the operator uses to adjust the hydraulic flow rate for the #1 auxiliary remote valve—has failed, has an open/short circuit, or is sending an out-of-range electrical signal to the controller.
Applies to these machines
8 machines- T4.80 to T4.110
- T6.140 to T6.175
- T6030 to T6090
- T7.170 to T7.315
- T7030 to T7070
- T8.275 to T8.435
- T9.435 to T9.700
- TG245
Check the cause
Inspect the wiring harness and connector leading to the 1st remote flow potentiometer for loose pins, corrosion, or pinched wires
Perform a component swap test by swapping the 1st remote flow potentiometer with the 2nd remote flow potentiometer to see if the fault code changes to the 2nd remote
Verify that the armrest controller is supplying the correct reference voltage to the sensor
Repair steps
Turn off the tractor and disconnect the battery
Prevent electrical shorts while working inside the armrest.
Remove the retaining screws to open the armrest console cover
Exposes the Electronic Draft Control (EDC) and EHR flow control section.
Locate the potentiometer
Locate the potentiometer for the 1st auxiliary remote valve.
Disconnect the electrical harness connector
Disconnect the electrical harness connector from the failed potentiometer.
Remove the flow control knob and retaining nut
Remove the flow control knob from the top of the armrest, then undo the retaining nut (typically a 3/8-32 nut) holding the potentiometer to the panel.
Remove the old potentiometer and install the new replacement part
Secure it with the retaining nut and reattach the knob.
Reconnect the electrical harness and reassemble
Reconnect the electrical harness and reassemble the armrest console.
Power on the tractor and clear the inactive fault codes
You may need to perform a remote valve calibration via the IntelliView / Pro700 monitor to ensure the new potentiometer's sweep is recognized by the controller.
Parts you might need
(2)EHR Flow Control Knob Potentiometer (1000 Ohm)
87663294Alternative/Superseded OEM Part Number: 87755846
3/8-32 Nut
A39888
Get help to fix this fault by requesting a quote