ARMRE 9012

New Holland ARMRE 9012 – Armrest Controller (ARM / ARMRE): Controller Memory Error - Loss of Aux Remote Lever Calibrations

Issue description

The controller has lost the saved calibration data for the auxiliary remote hydraulic levers from its non-volatile memory. This can be caused by a temporary voltage drop, a poor ground connection, or a physical defect within the controller's internal memory chip preventing it from retaining data.

Applies to these machines

  • TG215
  • TG245
  • TG275
  • TG305
  • T8010
  • T8020
  • T8030
  • T8040
  • T9 Series
  • MX210
  • MX230
  • MX255
  • MX285
  • 215
  • 245
  • 275
  • 305
  • Steiger Series

Check the cause

  1. Check battery and charging voltage to ensure it is not dropping too low during engine cranking, which can cause memory loss.

  2. Inspect connector C137 and verify the Armrest Controller has a clean, secure connection to the battery and is properly grounded.

  3. Power cycle the tractor completely (shut down, wait 30 seconds, restart) to see if the code is intermittent or hard-set.

Repair steps

  1. Access display monitor

    Turn the key switch to the ON position and access the tractor's display monitor (e.g., IntelliView or Pro 700).

  2. Navigate to Calibration Menu

    Navigate to the Calibration Menu for the Armrest Controller.

  3. Select AUX calibration

    Select the AUX (Auxiliary Remote Levers) calibration procedure.

  4. Stroke auxiliary remote levers

    Follow the on-screen prompts to fully stroke the auxiliary remote levers through their full range of motion (extend, retract, float) so the controller can relearn the potentiometer voltage values.

  5. Save and cycle key

    Save the calibration and cycle the key switch (turn off, wait, turn back on).

  6. Check for fault code

    Check if fault code ARM 9012 returns.

  7. Evaluate and replace controller if necessary

    If the calibration is successful and the code stays away, the issue was a temporary memory glitch. If the fault code appears again immediately or after a short period of use, the Armrest Controller's memory is defective. The Armrest Controller must be replaced. (Note: A new controller will require a dealer to use the CNH Electronic Service Tool (EST) to download the machine-specific software and perform a full calibration of all armrest functions).

Parts you might need

(3)
  • Armrest Controller

    84165726R

    Commonly fits Case IH Steiger and New Holland T9 models

  • Armrest Controller

    399285A1

    Commonly fits older Case IH MX Magnum and New Holland TG series

  • Joystick / Armrest Controller

    51575646

    Genuine OEM

Get help to fix this fault by requesting a quote

Browse other New Holland codes