E101
New Holland E101: Surface Speed Sensor (B7) Short to Ground
Issue description
The fault code indicates a short to ground in the circuit of the Surface Speed Sensor (B7). This condition may affect the proper operation of the sensor and the system it is connected to.
Check the cause
Surface Speed Sensor (B7) wiring
Connections to Surface Speed Sensor (B7)
Circuit integrity of Surface Speed Sensor (B7)
Repair steps
Inspect
Inspect the wiring and connections of the Surface Speed Sensor (B7) for damage, wear, or improper connections.
Test
Test the circuit of the Surface Speed Sensor (B7) for a short to ground using a multimeter or appropriate testing equipment.
Repair
If a short is found, repair or replace the affected wiring or connections of the Surface Speed Sensor (B7).