E114
New Holland E114: Short Circuit to +VE in the Elevator Sensor of Undergrinded
Issue description
A short circuit to +VE has been detected in the sensor of the elevator of undergrinded. This condition may affect the proper operation of the component identified by this code.
Check the cause
The wiring and connections of the sensor of the elevator of undergrinded
The integrity of the circuit associated with the sensor of the elevator of undergrinded
Repair steps
Inspect
Inspect the wiring and connections of the sensor of the elevator of undergrinded for signs of damage, wear, or improper contact.
Test
Test the circuit associated with the sensor of the elevator of undergrinded for continuity and proper insulation.
Parts you might need
(0)Get help to fix this fault by requesting a quote