New Holland EHR 4220 – EHR (Electro-Hydraulic Remote) Control Module: Rear Remote No.5 - Valve Spool Not Calibrated

Issue description

The controller has lost the calibration values for the 5th rear remote proportional valve spool, or a new, uncalibrated valve has been installed. Without these calibration values (which map the spool's neutral, maximum extend, and maximum retract positions), the remote valve cannot function properly.

Applies to these machines

  • New Holland T8.275
  • New Holland T8.300
  • New Holland T8.330
  • New Holland T8.360
  • New Holland T8.390
  • New Holland T8.420
  • New Holland T8010
  • New Holland T8020
  • New Holland T8030
  • New Holland T8040
  • New Holland T8050
  • New Holland T7.220
  • New Holland T7.235
  • New Holland T7.250
  • New Holland T7.260
  • New Holland T7.270

Check the cause

  1. Recent Service Check: Determine if the rear remote valve #5 or the EHR controller was recently replaced, or if the tractor's software was recently flashed, which can wipe calibration memory.

  2. Wiring & Connection Inspection: Inspect the wiring harness and connector at the #5 rear remote valve for corrosion, moisture, or backed-out pins that could cause a loss of communication.

  3. Operating Temperature: Ensure the tractor's hydraulic fluid is at normal operating temperature. Cold, thick hydraulic oil will skew the spool travel timing and cause calibration to fail.

  4. Valve Number Assignment: Each electro-hydraulic remote valve has a built-in processor. If the valve was replaced, verify that the processor has been digitally assigned its position number (in this case, Valve No. 5) in the remote stack.

Repair steps

  1. Warm Up the System

    Start the tractor and operate the hydraulics until the fluid reaches normal operating temperature.

  2. Assign the Valve Number (If Replaced)

    Replacement valve assemblies are supplied "blank" with no number assigned. Use the dealer service tool (EST) to program the valve's processor so it identifies itself as Valve No. 5.

  3. Set Engine Speed

    Set the tractor engine to the normal operating RPM specified in the service manual. This is critical because the calibration of the control levers is based on a time interval corresponding to how long it takes the cylinder rod to extend and retract.

  4. Enter Calibration Mode

    Access the tractor's calibration menu via the IntelliView display or the dealer service tool.

  5. Run the EHR Calibration

    Select the calibration procedure for Rear Remote No. 5. Follow the on-screen prompts to actuate the valve. The system will automatically stroke the spool to learn the neutral, extend, and retract parameters.

  6. Verify

    Save the calibration, cycle the key, and verify that the EHR 4220 code has cleared. If the calibration repeatedly fails, the valve actuator is likely mechanically binding or has a failed internal position transducer, requiring replacement.

Parts you might need

(4)
  • Electro-Hydraulic Remote Valve Assembly / Proportional Valve Actuator

    New valves are shipped unprogrammed. You must program the valve number into the new valve's processor before it will accept a calibration.

  • Rexroth Remote Valve

    84125295

    Fits New Holland T6000, TS-A series, and Case IH Maxxum/Puma. New valves are shipped unprogrammed.

  • Electric Spool Valve / Electro-Hydraulic Remote Valve Kit

    84230181

    Fits various CNH models. New valves are shipped unprogrammed.

  • 4-Section Remote Hydraulic Valve Assembly

    86024150

    New valves are shipped unprogrammed.

Get help to fix this fault by requesting a quote

Browse other New Holland codes