EHR 4302

New Holland EHR 4302 – EHR (Electro-Hydraulic Remote) Controller: Rear Remote No.6 - Implausible EHR Control Messages

Issue description

This code indicates a CAN bus communication error where the electronic control system is receiving invalid, erratic, or conflicting data messages regarding the #6 rear remote valve. This typically means there is a signal plausibility issue between the operator's armrest controls (joystick/levers) and the valve's internal controller, or the valve is failing to report its position correctly over the network.

Applies to these machines

  • T8.xxx Series
  • T9 Series
  • T6 Series (T6.120 - T6.180)
  • T7 Series (T7.170 - T7.210)
  • TSA Plus/Deluxe Series
  • Magnum 235-340 (Series 4)
  • Steiger equivalents

Check the cause

  1. Verify tractor battery voltage and ground connections, as low voltage or spikes can cause CAN communication errors.

  2. Inspect the wiring harness and the electrical connector directly at the #6 rear remote valve slice for moisture, corrosion, bent pins, or chafed wires.

  3. Perform a component isolation (swap test) by swapping the electrical connector from the #6 remote valve to an adjacent remote (e.g., #5) to determine if the fault follows the valve or stays with the wiring/controller.

  4. Check if the EHR lever/joystick has lost its calibration, which can cause the controller to read the lever's position as implausible.

Repair steps

  1. Power Down

    Turn off the tractor and disconnect the battery to safely reset the electronic control systems.

  2. Clean Connections

    Disconnect the harness at the #6 rear remote valve. Clean the contacts with electronic contact cleaner and apply dielectric grease to prevent moisture intrusion. Reconnect the harness securely.

  3. Re-calibrate the Valve

    Reconnect the battery and turn the key on. Access the tractor's display monitor and navigate to the Electro-Hydraulic Control Valve configuration menu.

  4. Stroke the Valve

    Initiate the calibration process for the #6 remote. Stroke the valves back and forth manually to clear internal debris before calibration. Follow the on-screen prompts to allow the system to learn the valve's neutral and end-stop positions.

  5. Replace Components

    If the valve fails to calibrate or the code immediately returns, replace the faulty EHR valve section or the EHR control switch/potentiometer on the armrest (depending on the results of your swap test).

  6. Clear Codes

    Use the tractor's diagnostic menu or a specialized dealer diagnostic tool to clear the EHR 4302 code and verify normal operation.

Parts you might need

(6)
  • EHR Control Valve Wire Harness

    84158327

    New Holland

  • EHR Valve Switch / Potentiometer (Armrest)

    82030280

    Fits New Holland T6, T7, and TSA series

  • 6-Spool EH Remote Kit (Complete Assembly)

    84319358
  • Electro-Hydraulic Remote (EHR) Valve Section

    Generic

  • CAN bus wiring pigtail

    Generic

  • EHR Joystick potentiometer

    Generic

Get help to fix this fault by requesting a quote

Browse other New Holland codes