EHR 4320

New Holland EHR 4320 – EHR: Rear Remote No.7 - Over Voltage

Issue description

The system has detected an abnormally high electrical voltage on the circuit responsible for controlling the 7th rear remote hydraulic valve.

Applies to these machines

  • New Holland T8.xxx Series
  • New Holland T9 Series

Check the cause

  1. Check if the tractor battery is currently connected to an external power supply (such as a high-output battery charger or jump box) that might be feeding excessive voltage into the system.

  2. Test the tractor's alternator and voltage regulator to ensure the charging system is not overcharging the electrical system.

  3. If system voltage is normal, inspect EHR valve #7 for a short or internal failure.

Repair steps

  1. Verify Power Sources

    Ensure no external power supplies or jump-starters are connected to the tractor's battery.

  2. Test Alternator Output

    Start the tractor and use a multimeter to check the voltage at the battery terminals. If the voltage exceeds normal operating limits (typically above 14.5V - 15V), diagnose and replace the alternator or voltage regulator.

  3. Inspect/Replace the Valve

    If the tractor's system voltage is within spec, the internal circuitry of Rear Remote Valve #7 has failed. Remove the faulty valve section from the rear hydraulic stack and install a replacement EHR valve.

  4. Clear and Calibrate

    Once the physical cause has been rectified, use a diagnostic tool to clear the EHR 4320 error code. Test the hydraulic system to ensure normal operation.

Parts you might need

(4)
  • Electronic Rear Remote Valve / EHR Spool Valve

    84230181

    Used on T6000 series / TS-A series

  • Double rear remote valve assembly

    47829237
  • Generic CNH rear remote valve

    719195010
  • Electronic Rear Remote Valve / EHR Spool Valve

    47675278

    Used on Workmaster series