New Holland ENG 3137 – Engine Control Unit (ECU / EDC / ECM): Fuel Metering Unit: Open Load of Metering Unit Output
Issue description
The engine controller has detected an "open load" (open circuit) in the electrical circuit that controls the Fuel Metering Unit. This broken electrical connection prevents the ECU from controlling the fuel pressure.
Applies to these machines
11 machines- L220
- SR175
- T5.95
- T5.105
- T5.115
- T7 series
- T8 series
- T9 series
- CR9090
- CX8080
- CX8090
Check the cause
Use the Electronic Service Tool (EST) to verify if ENG 3137 is active. If other codes are present (like short-to-ground or sensor supply codes), diagnose those first.
Locate the Fuel Metering Unit on the back of the Bosch high-pressure fuel pump. Disconnect the plug and inspect the pins for corrosion, backed-out terminals, or loose contacts.
Using a multimeter, check the continuity of the two wires running from the Fuel Metering Unit connector back to the Engine ECU. Look for chafed wires, broken wires, or a disconnected harness.
Measure the resistance across the two pins on the Fuel Metering Unit itself. A healthy solenoid typically shows very low resistance (0.2 to 0.4 ohms). If the multimeter reads 'OL' (Open Loop) or infinite resistance, the solenoid has failed internally.
Repair steps
Depressurize fuel system
Turn off the machine, remove the key, and wait for the fuel system pressure to drop. Clean the area around the high-pressure fuel pump thoroughly to prevent dirt from entering the fuel system.
Repair wiring harness
If diagnostic checks revealed a broken wire or damaged connector pin between the ECU and the metering unit, repair the harness using OEM-approved splice connectors or replace the pigtail connector.
Replace Fuel Metering Unit
If the solenoid tested open (infinite resistance), disconnect the electrical harness and remove the mounting screws securing the metering unit to the high-pressure fuel pump. Pull the unit straight out. Lubricate the O-rings on the new unit with clean diesel fuel, insert it into the pump housing, and torque the mounting screws to the manufacturer's specification.
Reassemble and test
Reconnect the electrical harness. Prime the low-pressure fuel system if necessary. Start the engine, check for fuel leaks, and use the Electronic Service Tool (EST) to clear the inactive fault codes.
Parts you might need
(8)Fuel Metering Unit
0928400481Bosch part. Very common on New Holland T7 series and Case IH equivalents.
Fuel Metering Unit
42541851CNH/Iveco interchange for Bosch 0928400481.
Fuel Metering Unit
84385110CNH/Iveco interchange for Bosch 0928400481.
Fuel Metering Unit
0928400617Bosch part for Doosan/CNH applications.
Fuel Metering Unit
0928400736Bosch part for FPT/Cummins engines.
Fuel Metering Unit
0928400821Bosch part for FPT/Cummins engines.
Fuel Metering Unit
5801976847FPT part for newer CR pumps.
Fuel Metering Unit
F00N210061Bosch interchange for FPT 5801976847.
Get help to fix this fault by requesting a quote