ENG 3140

New Holland ENG 3140 – Engine Control Unit (ECU) / Electronic Diesel Control (EDC): Fuel Metering Unit: Metering Unit Signal Range Check - Signal Too Low

Issue description

The Engine Control Unit (ECU) has detected that the sensing voltage for the fuel metering unit is less than 0.0 V, indicating the circuit is shorted to a low source (ground).

Applies to these machines

  • T5.95
  • T5.105
  • T5.115
  • T6
  • T7
  • T8
  • T9
  • CR9090
  • CX8080
  • CX8090
  • Skid Steer Loaders (SSL)
  • Compact Track Loaders (CTL)
  • W170B
  • W190B

Check the cause

  1. Connect an Electronic Service Tool to verify that the fault code is currently active

  2. Inspect the wiring harness between the ECU and the fuel metering unit on the high-pressure pump for rubbed-through insulation, pinched wires, or areas shorting to the engine block/ground

  3. Disconnect the metering unit and the ECU to inspect the pins for corrosion, moisture, or damage

  4. Use a multimeter to test the fuel high-pressure pump control circuit for a short to ground

  5. Measure the internal resistance of the fuel metering unit solenoid to determine if the unit itself has failed and shorted internally

Repair steps

  1. Disconnect Power

    Turn off the machine and disconnect the battery negative terminal to prevent electrical spikes.

  2. Repair Wiring

    If the diagnostic tests reveal a short to ground in the wiring harness, repair the damaged section of the wire or replace the affected harness section.

  3. Replace Metering Unit

    If the wiring tests good but the metering unit is internally shorted: Clean the area around the high-pressure fuel pump to prevent debris from entering the fuel system. Unplug the electrical connector from the fuel metering unit. Remove the mounting screws securing the metering unit to the high-pressure pump. Remove the faulty unit. Lubricate the O-rings on the new metering unit with clean diesel fuel. Carefully insert the new unit into the pump and torque the fasteners to OEM specifications.

  4. Reassembly

    Reconnect the electrical connector to the metering unit and reconnect the battery.

  5. Clear and Verify

    Use the Electronic Service Tool to clear the ENG 3140 fault code. Start the engine and monitor the common rail fuel pressure to ensure the system is operating within parameters and the code does not return.

Parts you might need

(8)
  • Fuel Metering Unit

    0928400481

    Bosch. Must match replacement part number to data tag on original high-pressure fuel pump.

  • Fuel Metering Unit

    42541851

    CNH cross-reference for Bosch 0928400481.

  • Fuel Metering Unit

    84385110

    CNH cross-reference for Bosch 0928400481.

  • Fuel Metering Unit

    5801382396

    CNH cross-reference for Bosch 0928400481.

  • Fuel Metering Unit

    0440030001

    Bosch. Must match replacement part number to data tag on original high-pressure fuel pump.

  • Fuel Metering Unit

    F00BC80045

    Bosch. Must match replacement part number to data tag on original high-pressure fuel pump.

  • Fuel Metering Unit

    0928400736

    Bosch. Must match replacement part number to data tag on original high-pressure fuel pump.

  • Fuel Metering Unit

    0928400821

    Bosch. Must match replacement part number to data tag on original high-pressure fuel pump.

Get help to fix this fault by requesting a quote

Browse other New Holland codes