New Holland ENG 3156 – Engine Control Module (ECM / EDC - Electronic Diesel Control): Grid Heater Relay - No Load
Issue description
The Engine Control Module (ECM) is commanding the grid heater relay to turn on (usually during a cold start sequence), but the ECM is not detecting any electrical load or current draw on the circuit. This points to an open circuit condition, meaning power is not reaching the grid heater element.
Applies to these machines
21 machines- T6.140
- T6.175
- T7.165S
- T7.175
- T7.190
- T7.210
- T7.225
- T7.290
- T7.315
- T8.350
- T6020
- CR9090
- CX8080
- CX8090
- B90B
- B100B
- B110B
- B115B
- W190B
- Magnum
- Puma
Check the cause
Check the Fuses: The grid heater system draws a massive amount of current and is protected by heavy-duty fuses. Check the 150 Amp Mega Fuse on the main power line, as well as the smaller control circuit fuse (often a 15A mini fuse, designated for the K-023 or K-053 relay depending on the model).
Inspect the Wiring Harness: Visually inspect the wiring harness running from the battery to the grid heater relay, and from the relay to the grid heater element. Look for broken wires, melted insulation, or loose terminal connections.
Test the Relay: Locate the grid heater relay (often mounted on an engine frame bracket or near the starter/alternator harness). Test for voltage at the relay input. Jump the relay to see if the grid heater engages; if it does, the relay itself or the ECM trigger wire is faulty.
Test the Grid Heater Element: Check the grid heater element for continuity using a multimeter. If the element is burnt out (open circuit), it will not draw a load, triggering this code.
Repair steps
Disconnect Power
Always disconnect the negative battery cable before working on the grid heater circuit, as the main power cable is directly connected to the battery and carries high amperage.
Access the Relay
Locate the grid heater relay. On many T6 and T7 tractors, it is mounted to an engine frame bracket on the right-hand side. You may need to detach the Air Conditioning (A/C) pipe retaining bracket to access it.
Replace Blown Fuses
If the 150A mega fuse or the 15A control fuse is blown, unbolt the old fuse and install a new one. (Note: If the mega fuse is blown, check the main power cable for a short to ground before reconnecting power).
Replace the Relay / Harness
Disconnect the electrical connectors from the grid heater relay. Unbolt the relay bracket and remove the faulty relay. If the wiring harness is corroded or burnt at the connector, remove the damaged harness section (cutting zip ties as necessary) and install a replacement harness. Install the new relay and reconnect the electrical terminals securely.
Reassembly and Clearing Codes
Reconnect the battery. Turn the key to the ON position to initiate the cold start sequence. The ECM should now detect the load. Clear the stored fault codes using the CNH Electronic Service Tool (EST), or allow the system to clear the active code after a successful start cycle.
Parts you might need
(4)Grid Heater Relay Wiring Harness
47679309Specific to T7 Series Tier 4B (Fits T7.165S, T7.175, T7.190, T7.210, T7.225)
150 Amp Mega Fuse
8501311Bussman 150 Amp
15A Mini Fuse (Blue)
87524877Supersedes older part # 84127703
Grid Heater Relay
Often referenced in diagrams as Relay K-023 or K-053; exact OEM part number depends heavily on the specific machine's serial number and tier emissions level
Get help to fix this fault by requesting a quote