ENG 381

New Holland ENG 381 – Engine Controller (Engine ECU / ECM): Error detected in cold start relay 1

Issue description

This code indicates a malfunction, voltage irregularity, or open/short circuit in the primary cold start relay circuit. This relay is responsible for sending high-amperage current to the intake air heater (or grid heater) to warm the incoming air, which assists the diesel engine in starting during cold weather. When this relay fails, the engine may experience hard starting, insufficient heat generation, and emit white smoke during cold cranks.

Applies to these machines

  • T8 Series
  • T9 Series
  • Magnum equivalents
  • CR9090
  • CX8080
  • CX8090
  • CX210
  • CX240
  • E215
  • 580 Super M series
  • Patriot 350
  • Trident 5550

Check the cause

  1. Perform a battery load test and ensure terminals are clean and tight, as a weak battery can cause relays to fail to engage.

  2. Inspect the wiring harness between the Engine ECU and the cold start relay, specifically checking pin 41 of the OEM harness for continuity and proper voltage.

  3. Bench test the cold start relay for internal shorts or open circuits, and listen for an audible click when the key is turned to the ON position in cold conditions.

  4. Inspect the heavy-duty inline fuse (often 300-amp) located near the battery or junction block to ensure it has not blown.

Repair steps

  1. Disconnect Batteries

    Disconnect the negative battery cable(s) first, followed by the positive cable(s) to prevent accidental arcing or short circuits.

  2. Locate the Relay

    Locate Cold Start Relay 1. It is typically mounted on a bracket near the engine intake manifold grid heater or inside the main engine compartment fuse/relay box.

  3. Remove Wiring

    Disconnect the heavy-gauge positive cables from the relay's primary studs. Then, disconnect the smaller control wires (or wiring harness plug) that run to the Engine ECU.

  4. Dismount the Relay

    Remove the mounting bolts (usually M6 or M8 bolts) securing the relay to its mounting plate or spacer bar.

  5. Install the New Relay

    Bolt the replacement cold start relay into place.

  6. Reconnect Wiring

    Reattach the control wires and the heavy-gauge power cables. Ensure the nuts on the high-amperage studs are torqued to OEM specifications to prevent arcing.

  7. Restore Power

    Reconnect the positive battery cable(s), followed by the negative cable(s).

  8. Verify Repair

    Turn the ignition key to the ON position. Verify that the grid heater cycles on (watch for the wait-to-start light) and ensure the ENG 381 code is no longer active.

Parts you might need

(3)
  • Cold Start Relay (Grid Heater Relay)

    86619908

    Primary heavy-duty relay used for the cold start grid heater on CNH Tier 3 / Tier 4 engines.

  • Standard SPDT Relay (Alternative/Auxiliary)

    86529089

    Used in various New Holland skid steers and backhoes for cold start and main power circuits.

  • 300 Amp Fuse

    87410602

    Protects the cold start grid heater circuit; should be replaced if the relay failed due to a dead short.

Get help to fix this fault by requesting a quote