ENG 3842

New Holland ENG 3842 – Engine Control Unit (ECU) / EDC7: Turbine Upstream Temperature Sensor: SRC High

Issue description

The Engine Control Unit (ECU) has detected that the voltage signal from the inlet turbo temperature sensor is abnormally high (specifically, above 3.59 V). This indicates that the sensor's signal circuit is shorted to a high-voltage source.

Applies to these machines

  • W50C ZB
  • W60C ZB
  • W70C HS
  • W70C
  • W80C HS
  • W80C
  • CR9090
  • CX8080 Elevation
  • CX8090 Elevation Tier 4A
  • T6
  • T7
  • T8
  • T9

Check the cause

  1. Connect the Electronic Service Tool (EST) to verify that fault code 3842 is currently active

  2. Inspect the wiring harness between the turbine upstream temperature sensor and the ECU for chafed wires, melted insulation, or pinched harnesses causing a short to power

  3. Disconnect the sensor and check if the voltage on the signal wire drops. If voltage remains high, the short is in the harness. If it normalizes, the sensor has failed internally

  4. Test the ECU: If the wiring harness is completely intact but the high voltage originates from the ECU pin itself, the control unit may be faulty

Repair steps

  1. Turn off the machine and disconnect the battery

    Ensure safety while working on the engine wiring harness.

  2. Locate the turbine upstream temperature sensor

    Locate the inlet turbo temperature sensor near the turbocharger assembly.

  3. Inspect the electrical connector

    Disconnect the sensor's electrical connector and inspect the pins for corrosion, moisture, or damage.

  4. Repair or replace the wiring harness

    Repair or replace any damaged sections of the wiring harness if a short to power was found during the diagnostic phase.

  5. Remove the faulty sensor

    If the wiring is good but the sensor failed the diagnostic test, unthread the faulty temperature sensor from the exhaust/turbo housing.

  6. Install the new temperature sensor

    Install the new temperature sensor and torque it to the manufacturer's specification.

  7. Reconnect the electrical connector and battery

    Reconnect the electrical connector and the battery.

  8. Verify the repair

    Connect the Electronic Service Tool, clear the inactive fault codes, and run the engine to verify that the code does not return and the sensor reads normal operating temperatures.

Parts you might need

(1)
  • Turbine Upstream Temperature Sensor

    Also known as the Inlet Turbo Temperature Sensor. Look up the exact part number in the CNH parts catalog using the specific machine's PIN/Serial Number.