New Holland ENG 466 – ENG: Wastegate 1 voltage is too low
Issue description
The engine control module is receiving a voltage signal from the turbocharger's electronic wastegate actuator (or its position sensor) that falls below the minimum acceptable threshold. This condition is typically caused by a short to ground in the wiring harness, a disconnected plug, or an internal failure of the electronic wastegate actuator itself.
Applies to these machines
6 machines- T7 Series (e.g., T7.270)
- CR Series (e.g., CR9090)
- CX Series (e.g., CX8080, CX8090 Tier 4A)
- FR Series (e.g., FR450)
- Magnum tractors
- STS combines
Check the cause
Inspect the wiring harness leading to the turbocharger Wastegate 1 actuator for chafed wires, melted insulation from exhaust heat, or a disconnected plug
Disconnect the wastegate actuator harness and check for water intrusion, bent pins, or corrosion inside the connector
Turn the key to the ON position (engine off) and use a multimeter to verify that the actuator is receiving the proper 5-volt reference signal and has a solid ground
Test the pins on the wastegate actuator itself to determine if the internal potentiometer/sensor has shorted out
Disconnect the actuator arm and verify that the physical wastegate valve on the turbocharger moves freely to ensure a seized flap is not burning out the motor
Repair steps
Disconnect Power
Turn off the machine and disconnect the negative battery cable to prevent electrical spikes.
Wiring Repair
If a short to ground or broken wire was found during diagnostics, splice and repair the wiring harness using heat-shrink connectors, or replace the damaged pigtail section.
Actuator Replacement
If the actuator failed the electrical test, remove the retaining clip securing the actuator rod to the wastegate valve. Remove the mounting bolts holding the actuator to the turbocharger compressor housing. Install the new actuator, secure the mounting bolts, and reattach the linkage arm with a new retaining clip. (Note: On some VGT/electronic turbochargers, the actuator is calibrated to the turbo and cannot be purchased separately; the entire turbocharger assembly must be replaced).
Reassembly
Reconnect the electrical harness to the actuator.
Calibration & Clearing
Reconnect the battery. Connect the CNH Electronic Service Tool (EST) to clear the inactive ENG 466 fault code. Some electronic wastegates may require a relearn/calibration procedure via the EST software so the ECU learns the new end-stops.
Test Run
Start the engine and run it under load to verify that boost pressure is within normal parameters and the code does not return.
Parts you might need
(4)Electronic Wastegate Actuator / Turbocharger Assembly
5802076062CNH OEM Part Number
Electronic Wastegate Actuator / Turbocharger Assembly
5802741343CNH OEM Part Number
Electronic Wastegate Actuator / Turbocharger Assembly
827728-0001Garrett Motion SKU
Wiring Harness Pigtail
Generic Turbo actuator connector repair kit