New Holland IC 9004 – IC (Instrument Cluster): Memory Error - Triple Redundant - Hour Meter - Location 1 Corrupt
Issue description
The machine's hour meter data is stored using a triple-redundancy safeguard within the memory chip. This code indicates that the data stored in the first of these three memory locations has become corrupted or damaged.
Applies to these machines
17 machines- L213
- L215
- L216
- L218
- L220
- L221
- L223
- L225
- L228
- L230
- C227
- C232
- C237
- C238
- B90B
- B100B
- TR270
Check the cause
Connect the Electronic Service Tool (EST) to the machine's service plug to establish communication with the cluster.
Check for companion codes IC 9005 (Location 2 Corrupt) or IC 9006 (Location 3 Corrupt), which indicate a total memory failure.
Attempt a software update or reflash of the Instrument Cluster via the EST to see if the memory corruption can be overwritten.
Repair steps
Disconnect battery
Turn off the machine's ignition and disconnect the negative battery cable.
Remove mounting hardware
Remove the mounting hardware securing the instrument cluster panel to the cab interior.
Disconnect wiring harness
Carefully pull the cluster forward and disconnect the main wiring harness connector from the back of the unit.
Install new cluster
Connect the wiring harness to the new replacement Instrument Cluster and mount it back into the cab panel.
Reconnect battery
Reconnect the negative battery cable.
Program new cluster
Connect the EST to the machine. You must program the new instrument cluster, as replacement clusters do not come with software preloaded due to their dependency on the specific machine model they are installed in.
Parts you might need
(6)Instrument Cluster
47522654Replaces older part number 84413348. Must be programmed via EST after installation.
Instrument Cluster
84413348Older part number replaced by 47522654.
Instrument Cluster
84384716Replaces older part number 84239242. Must be programmed via EST after installation.
Instrument Cluster
84239242Older part number replaced by 84384716.
Instrument Cluster
84239243RRemanufactured option. Must be programmed via EST after installation.
Instrument Cluster
91789483RRemanufactured option. Must be programmed via EST after installation.
Get help to fix this fault by requesting a quote