New Holland INST 10038 – INST: Controller Memory Error - Loss of Valid Remote Timer information
Issue description
The controller has lost the saved configuration data or memory parameters associated with the remote timer settings.
Applies to these machines
22 machines- T8010
- T8020
- T8030
- T8040
- T8050
- T9020
- T9030
- T9040
- TG215
- TG230
- TG245
- TG255
- TG275
- TG285
- TG305
- Magnum 215
- Magnum 245
- Magnum 275
- Magnum 305
- Magnum 335
- MX Series
- Steiger Series
Check the cause
Check the instrument cluster menus to confirm that the remote timer settings are actually missing, blank, or corrupted
Inspect the tractor's battery health, battery cables, and the specific power/ground harness connections leading to the instrument cluster (A-post cover area) for sudden voltage loss
Attempt to manually re-enter the remote timer settings and cycle the tractor's key power to see if the cluster successfully retains the new settings
Repair steps
Reset and Reload
Reset the remote timer and reload the configuration settings manually through the instrument cluster interface.
Save Configuration
Once the remote timer parameters are re-entered, save the settings and reboot the tractor's electrical system.
Evaluate EEPROM Health
If the INST 10038 code returns immediately, or if the cluster drops the settings again after a power cycle, the internal EEPROM (memory) of the instrument cluster is failing.
Replace Cluster
If the memory failure is permanent, the instrument cluster/dash panel must be physically replaced and reprogrammed to the tractor.
Parts you might need
(3)Instrument Cluster / Dash Panel
87493959Replaces older part number 87382886
Instrument Cluster / Dash Panel
87382886Older part number replaced by 87493959
Instrument Cluster / Dash Panel
87673423Related OEM dash panel assembly number
Get help to fix this fault by requesting a quote