NH 1020

New Holland NH 1020 – EDC (Electronic Draft Control) module: Load sensing pin voltage too high

Issue description

The returned signal voltage from the load sensing pin exceeds the programmed upper limit (short to +12 Volt or an 8V reference voltage that is too high), causing the system to disable draft control.

Applies to these machines

  • T5
  • T5.95
  • T5.105
  • T5.115
  • T6
  • T7
  • T8
  • T9
  • TM
  • TG
  • 60 series

Check the cause

  1. Visually inspect the wiring harness and connectors leading to the lower link load sensing pins for corrosion, water ingress, or chafing that could cause a short to +12V.

  2. Verify the main earth/ground connections at the battery and at the back of the cab. Bad grounds are a known cause of intermittent high-voltage EDC errors.

  3. Measure the supply voltage at the pin connector. It should receive an 8V (or 8.5V) reference voltage.

  4. Measure the signal voltage returning to the controller. With no load on the pin, the signal voltage should be exactly half of the supply voltage.

  5. Test the internal resistance of the pin. For a standard 60 kN pin, resistance between pins 1 and 3 should be approximately 9170 Ω; between pins 1 and 2 should be 178 Ω; and between pins 2 and 3 should be 178 Ω. If it fails these checks, the internal strain gauge has failed.

Repair steps

  1. Disconnect battery

    Disconnect the tractor's battery.

  2. Disconnect harness

    Disconnect the electrical harness from the faulty load sensing pin.

  3. Remove faulty pin

    Remove the retaining hardware (flange bolts/snap rings) and slide the faulty load sensing pin out of the lower link arm draft bracket.

  4. Clean mounting bore

    Clean the mounting bore thoroughly to ensure the new pin seats without binding.

  5. Install new pin

    Install the new load sensing pin. Note: The fixing flange ensures correct pin orientation; it is directional and must be installed in the correct position to measure the load properly.

  6. Reconnect harness and battery

    Reconnect the wiring harness and the battery.

  7. Perform Autocalibration

    Perform the Hydraulic Lift Autocalibration (must be completed before the hitch will operate normally, often clearing code NH 1024).

  8. Disconnect harness (Alternative Repair)

    If installing a Draft Load Sensing Pin Elimination Kit (for tasks not requiring draft sensing), disconnect the harness from the faulty pins.

  9. Install elimination modules

    Plug the elimination modules directly into the tractor's wiring harness to send a permanent 'zero load' signal back to the EDC.

  10. Secure modules

    Secure the modules and wiring out of the way using tie wraps.

Parts you might need

(7)
  • Load Sensing Pin (Draft Sensor Pin)

    87661279

    Fits various T-series

  • Load Sensing Pin (Draft Sensor Pin)

    87351611

    Fits T8 series / TG series

  • Load Sensing Pin (Draft Sensor Pin)

    47800256

    Fits T7 series

  • Load Sensing Pin (Draft Sensor Pin)

    44503

    Fits T7 series

  • Load Sensing Pin (Draft Sensor Pin)

    322022A1

    Fits T8010-T8050, TG210-TG305

  • Draft Load Sensing Pin Elimination Kit

    47137583

    Fits T6000, T7, TM series, and TG series

  • Draft Load Sensing Pin Elimination Kit

    87661289

    Fits T6000, T7, TM series, and TG series