NH 1025

New Holland NH 1025 – EDC (Electronic Draft Control) Module / Hitch Controller / Armrest Module (ARU): Mouse lift lever potentiometer signal too low.

Issue description

This code indicates a fault in the Electronic Draft Control (EDC) system. Specifically, the voltage signal returning from the potentiometer inside the "EDC mouse" (the multi-function hitch control lever/pod) has dropped below the minimum acceptable threshold, typically indicating an open circuit, a short to ground, or a failed internal potentiometer.

Applies to these machines

  • T6 Series
  • T6010
  • T6020
  • T6050
  • T6070
  • T7 Series
  • T7.220
  • T7.235
  • T7.250
  • T8 Series
  • T8.275
  • T8.330
  • T8.390
  • T9 Series
  • TM Series
  • Genesis series

Check the cause

  1. Check for related 5-volt reference codes (such as NH 1053 or NH 1054). If present, the issue may be a shared power supply rather than the mouse itself.

  2. Inspect the wiring harness and connectors between the EDC mouse and the controller for pinched wires, chafing, or disconnected plugs.

  3. Disconnect the EDC mouse and probe the harness connector with a multimeter to verify that the controller is supplying a steady 5V reference and a good ground to the sensor.

  4. Check the signal wire for continuity back to the EDC/Armrest controller, and ensure it is not shorted to ground.

  5. Test the resistance/voltage sweep of the mouse potentiometer while moving the lift lever. If the signal drops out, stays low, or has dead spots, the potentiometer/mouse assembly has failed internally.

Repair steps

  1. Power Down

    Turn off the tractor, remove the key, and disconnect the battery to prevent electrical spikes.

  2. Access the Mouse

    Remove the trim panels on the right-hand console or the SideWinder™ II armrest to expose the mounting hardware for the EDC mouse assembly.

  3. Disconnect

    Unplug the electrical connector(s) leading to the EDC mouse.

  4. Remove & Replace

    Remove the retaining screws holding the mouse assembly in place. Install the new EDC mouse assembly and secure the hardware.

  5. Reassemble

    Reconnect the wiring harness and reinstall the armrest/console trim panels.

  6. Calibration

    Reconnect the battery and turn the key on. Perform a Hydraulic Lift Autocalibration (often prompted by code NH 1024) to teach the controller the new potentiometer's minimum and maximum voltage values.

Parts you might need

(7)
  • EDC Mouse

    84172499

    Common on T8 series; Replaced by 91717659

  • EDC Mouse

    91717659

    Replaces 84172499

  • Control EDC Mouse

    91717662

    Common on various CNH models

  • Legacy EDC Mouse

    805020010/10

    Legacy EDC Mouse part number (often sent out for aftermarket repair/rebuild)

  • Legacy EDC Mouse

    82024389

    Legacy EDC Mouse part number (often sent out for aftermarket repair/rebuild)

  • Legacy EDC Mouse

    82024839

    Legacy EDC Mouse part number (often sent out for aftermarket repair/rebuild)

  • Legacy EDC Mouse

    82034652

    Legacy EDC Mouse part number (often sent out for aftermarket repair/rebuild)

Get help to fix this fault by requesting a quote