NH 14022

New Holland NH 14022 – ADIC (Advanced Digital Instrument Cluster): Radar Ground speed short to Ground

Issue description

The signal voltage from the radar ground speed sensor is being unexpectedly pulled to 0 volts. This condition is typically caused by a wiring harness short (a bare wire touching the tractor's metal chassis) or an internal short circuit within the radar sensor itself.

Applies to these machines

  • T4.75F
  • T5 series
  • T5.95
  • T5.105
  • T5.115
  • T7 series
  • T8040
  • T8050
  • Workmaster 50
  • 70 Series
  • 8670
  • 8770
  • 8870
  • 8970
  • TL Series
  • TL70-TL100
  • TM Series
  • TM115-TM165
  • TS Series
  • TSA Series
  • 40/60 series
  • 5640
  • 6640
  • 8160
  • 8240
  • 8340
  • 9000 series

Check the cause

  1. Trace the wiring harness from the radar ground speed sensor to the ADIC/Instrument cluster. Look for pinched wires, chafing, or bare spots where the signal wire might be grounding out against the tractor frame.

  2. Inspect the radar sensor connector (commonly a 4-wire, 4-prong round plug) for moisture, corrosion, or bent pins that could bridge the signal wire to the ground wire.

  3. Disconnect the radar sensor from the harness and turn the key on. Check if the 'short to ground' code changes to an 'open circuit' code (such as NH 14021) to determine if the sensor itself is internally shorted.

Repair steps

  1. Power Down

    Turn off the tractor and disconnect the battery ground cable to prevent electrical spikes.

  2. Repair Wiring

    If a short is found in the harness during diagnostics, splice and heat-shrink the damaged section of the wire, or replace the affected harness pigtail.

  3. Replace Sensor

    If the sensor is internally shorted, unbolt the faulty radar sensor from its mounting bracket under the cab/chassis.

  4. Install New Sensor

    Mount the replacement radar sensor. Ensure it is angled correctly according to your specific model's service manual, as radar alignment is critical for accurate speed reading.

  5. Reconnect and Calibrate

    Plug in the 4-prong connector. Reconnect the battery. On some models, you may need to access the instrument cluster menu to input the tire size and recalibrate the radar gun settings.

  6. Test

    Clear the fault codes and test drive the tractor to verify that the ground speed registers accurately on the dash without throwing NH 14022.

Parts you might need

(6)
  • Radar Ground Speed Sensor / True Ground Speed Sensor

    82011249

    Fits Ford/New Holland 70 Series, TL Series, and TM Series.

  • Radar Ground Speed Sensor / True Ground Speed Sensor

    82018367

    Alternative to 82011249

  • Radar Ground Speed Sensor

    82009402

    4-wire, round plug radar sensor. Fits 5640, 6640, 8160, 8240, 8340, 8670, 8770, 8970, and 9000 series.

  • Radar Ground Speed Sensor

    82021162

    Fits TL, TM, TS, and TSA Series.

  • True Ground Speed Row Sensor

    87733890

    Newer style

  • Radar Sensor

    84465662

    Newer style

Get help to fix this fault by requesting a quote

Browse other New Holland codes