NH 4122

New Holland NH 4122 – EHR (Electronic Hydraulic Remote) Controller / ARU (Arm Rest Unit) / Aux Controller: Rear Remote No.2 - Float position not reached

Issue description

When the operator commands the #2 rear remote valve to the 'Float' position, the Electronic Hydraulic Remote (EHR) valve actuates the spool. However, the internal spool position sensor fails to detect that the spool has physically traveled far enough to reach the float detent/position. This is typically caused by mechanical binding in the valve spool, a failing position potentiometer, or an out-of-calibration sensor.

Applies to these machines

  • T6 Series
  • T7 Series
  • T8 Series
  • T9 Series
  • T6000 Series
  • TG Series
  • Auto Command tractors
  • Power Command tractors

Check the cause

  1. Manually stroke the #2 remote valve back and forth (using the manual override levers on the valve body, if equipped) to clear any potential debris and check for physical spool binding.

  2. Inspect the wiring harness and the connector at the #2 rear remote valve potentiometer for corrosion, moisture, or backed-out pins.

  3. Look for other codes on Remote No.2 (such as 4124 Driver Faulty, 4125 Potentiometer Faulty, or 4118/4119 Voltage errors) which would point strictly to an electrical failure rather than a mechanical spool jam.

  4. Attempt to run the EHR valve calibration procedure through the tractor's in-cab display. If the valve fails calibration, the sensor or valve section is faulty.

Repair steps

  1. Relieve Pressure

    Park the tractor on a level surface, lower all implements, turn off the engine, and cycle the hydraulic levers/joysticks to relieve residual hydraulic pressure.

  2. Locate the Valve

    Locate the rear remote valve stack at the back of the tractor and identify the #2 valve section.

  3. Remove the Sensor

    Disconnect the electrical harness from the potentiometer/position sensor located on the end cap of the #2 valve section. Unbolt and remove the sensor.

  4. Inspect the Spool

    Verify that the internal spool moves freely. If the spool is heavily scored, jammed, or the return spring is broken, the entire valve section will need to be removed and rebuilt/replaced.

  5. Replace the Potentiometer

    If the spool moves freely but the float position is not being read, the potentiometer has failed (a highly common issue). Install a new OEM potentiometer onto the valve body.

  6. Reassemble

    Reconnect the wiring harness to the new sensor.

  7. Calibrate the Valve

    Turn the tractor key to the ON position. Access the EHR calibration menu via the tractor's display monitor. Run the automated valve calibration sequence. The controller will stroke the valve to learn the new sensor's voltage limits for neutral, extend, retract, and float.

Parts you might need

(5)
  • EHR Remote Valve Potentiometer / Spool Position Sensor

    87605245

    Potentiometer - common on T7000 / T7 series

  • EHR Remote Valve Potentiometer / Spool Position Sensor

    47876591

    Potentiometer - common on various CNH models

  • EHR Remote Valve Potentiometer / Spool Position Sensor

    82024131

    Potentiometer for 1st/2nd or 3rd/4th remote valves on TM series

  • EHR Remote Valve Potentiometer / Spool Position Sensor

    82024132

    Potentiometer for 1st/2nd or 3rd/4th remote valves on TM series

  • Complete Valve Section

    87328572

    Rexroth complete replacement EHR valve section (e.g., for T6030)

Get help to fix this fault by requesting a quote

Browse other New Holland codes