NH 4170

New Holland NH 4170 – EHR (Electronic Hydraulic Remote) Controller: EHR Control No. 1 not calibrated

Issue description

Spool travel calibration data for the #1 Electronic Hydraulic Remote (EHR) valve is missing or out of range.

Applies to these machines

  • T6 / T6000 Series (T6030, T6.140)
  • T7 / T7000 Series (T7.220, T7.235, T7.250, T7.260, T7.270)
  • T8 Series (T8.390)
  • T9 Series (T9.390, T9.450, T9.560)

Check the cause

  1. Check for Communication Codes: Verify if code 4190 (EHR 1 Offline Err) is also present. If active, it indicates a wiring harness failure or dead valve processor rather than just a calibration issue.

  2. Clear Debris: Stroke the manual override lever on the valve back and forth to clear any internal debris or sticking spools before attempting electronic calibration.

  3. Swap Test: Swap the wiring harness connectors between the #1 and #2 remote valve powerheads. If the fault moves to #2, the #1 valve powerhead/solenoid is faulty. If it stays on #1, the issue is in the wiring harness, armrest switch, or controller.

Repair steps

  1. Secure tractor

    Park the tractor safely away from obstacles, firmly apply the parking brake, and block the wheels.

  2. Disconnect implements

    Disconnect all implements from the rear remotes.

  3. Turn off switches

    Ensure all EHR program switches on the armrest are in the OFF position.

  4. Install diagnostic tool

    Install the Diagnostic Connector Jumper (OEM Tool # 380000843) into the tractor's diagnostic socket. (Note: On larger articulated models like the T9 or T7 AutoCommand, a pressure transducer tool, OEM # 380001903, must be connected to the quick release coupler on the valve block).

  5. Turn ignition ON

    Turn the ignition key switch ON.

  6. Navigate to calibration menu

    Use the instrument cluster keys or A-post display to navigate to the 'H1' menu and select the rear EHR symbol. The lower central display will show 'CAL'.

  7. Perform calibration

    Depress the program switch for lever No.1. The system will prompt you to stroke the lever to maximum extend, maximum retract, and neutral.

  8. Retry calibration if needed

    If calibration fails the first time, stroke the valve back and forth manually for a while to free up the spool, then attempt the calibration again.

  9. Replace failed components

    If the system refuses to calibrate, the EHR valve powerhead or the armrest lever potentiometer has failed and must be replaced.

Parts you might need

(4)
  • EHR Remote Valve / Powerhead

    87328572

    Rexroth / CNH OEM for T6000 series

  • EHR Armrest Switch / Lever Potentiometer

    82030280

    CNH OEM for T6/T7 series

  • Diagnostic Jumper Connector Tool

    380000843

    Required to enter calibration mode on many models

  • Calibration Pressure Transducer Tool

    380001903

    Required for T7 AutoCommand and T9 series valve calibration

Get help to fix this fault by requesting a quote

Browse other New Holland codes