New Holland NH 4171 – DU (Drive Unit / Display Unit) Control Module: Rear EHR Control No.1 Open Circuit

Issue description

This code indicates that the electrical circuit for the Electronic Hydraulic Remote (EHR) control lever or spool number 1 has an open circuit. This condition is typically caused by a broken wire, a disconnected plug, or a failed potentiometer/switch inside the control lever assembly.

Applies to these machines

  • T6000 Series
  • T6010
  • T6020
  • T6030
  • T6040
  • T6050
  • T6060
  • T6070
  • T7000 Series
  • T7030
  • T7040
  • T7050
  • T7060
  • T7 Series
  • T7.220
  • T7.235
  • T7.250
  • T7.260
  • T7.270
  • T9 Series
  • T9.390
  • T9.450
  • T9.505
  • T9.560
  • T9.615
  • T9.670
  • T5000 Series
  • T5040-T5070
  • TM Series

Check the cause

  1. Inspect the wiring harness and connectors between the EHR Control Lever No.1 (in the cab/armrest) and the DU control module for broken wires, chafing, or backed-out pins

  2. Inspect the 4-pin connector at the rear remote valve No.1 for corrosion, moisture, or damage

  3. Use the H9 menu on the instrument cluster to check the lever potentiometer in H9 Channel 55. Values should change continuously between 10 and 90 when operating the lever from float to extend

  4. Verify the CAN BUS communication lines for continuity and proper voltage

Repair steps

  1. Disconnect Power

    Disconnect the battery power before beginning electrical repairs.

  2. Repair Wiring

    Repair any broken wires or replace damaged connectors found during the diagnostic checks.

  3. Replace Faulty Components

    If the H9 menu test confirms the EHR control lever potentiometer is dead and the wiring is intact, replace the EHR control lever assembly. If the remote valve spool actuator itself has an internal open circuit, replace the actuator/valve.

  4. Clear Codes

    Reconnect the battery, turn the key on, and clear the error code.

  5. Perform Calibration

    After repairing the wiring or replacing the lever/valve, you must perform a spool travel calibration (EHR valve calibration). Failing to calibrate the new component will immediately throw a related code: NH 4170.

Parts you might need

(3)
  • EHR Control Lever Assembly / Joystick

    47977310

    EHR Armrest Assembly / Joystick - includes harness, micro button, encoder, and LED module

  • EHR Remote Valve Actuator

    719411144

    Electrohydraulic Remote Valve Kit

  • Electrical Connector (4-Pin)

    87694154

    Replaces older part 225326C1; 4-pin male connector for the remote valve to rear frame harness

Get help to fix this fault by requesting a quote