New Holland P20C2 – DCU or ECM: Reagent Suction Tube Heating Detection Mode Issue

Issue description

The engine's control system has detected that the performance of the Diesel Exhaust Fluid (DEF) suction tube heating circuit is outside of its expected operational parameters. This indicates that the circuit may be open, shorted, or the heater is not drawing the correct amount of electrical current. The reagent suction tube heater is a critical component of the Selective Catalytic Reduction (SCR) system, designed to prevent DEF from freezing in cold operating conditions.

Applies to these machines

  • T6.120
  • T6.140
  • T6.150
  • T6.155
  • T6.160
  • T6.165
  • T6.175
  • T7.170
  • T7.185
  • T7.200
  • T7.210
  • T7.220
  • T7.235
  • T7.250
  • T7.260
  • T8 Series
  • T9 Series
  • CR6090
  • CR7090
  • CR8080
  • CR8090
  • CR8.90
  • CR9090
  • CR9.90
  • CX8070
  • CX8090

Check the cause

  1. Visually inspect the wiring harness and connectors associated with the DEF tank and supply module for frayed wires, broken wires, corrosion on pins, or loose connections

  2. Check for any other active or stored fault codes related to the SCR system to provide additional diagnostic context

  3. Locate and inspect the fuses and relays that supply power to the DEF heater circuits for blown fuses or faulty relays

  4. Perform a circuit voltage and continuity test at the reagent suction tube heater connector to rule out an open or short circuit in the wiring to the control module

  5. Disconnect the heater and measure its internal resistance with a multimeter, comparing the reading to manufacturer specifications (infinite resistance indicates an open circuit; very low resistance indicates a short)

Repair steps

  1. Repair wiring and power supply

    If diagnostic checks reveal issues with wiring, connectors, fuses, or relays, repair or replace these components first. Clear the fault codes and re-test the system to see if the P20C2 code returns.

  2. Replace DEF supply module

    If the heater element fails the resistance test, the component must be replaced. The reagent suction tube heater is typically integrated into the DEF supply module or pump assembly within the DEF tank, requiring replacement of the larger assembly.

  3. Replace control module

    If the heater tests within specifications but the control circuit is still malfunctioning, the issue may lie with the Dosing Control Unit (DCU) or the Engine Control Module (ECM). Consider this only after all other possibilities have been exhausted.

  4. Verify system operation

    After repairs, clear the fault codes using a diagnostic tool. Perform a system functional test, initiate a specific SCR system verification procedure via the diagnostic tool, or allow the vehicle to complete a drive cycle to ensure the fault does not reappear.

Parts you might need

(3)
  • Example part number that fits many New Holland and Case IH models. The heater is integrated into this assembly. Verify exact part number by machine serial number.

  • 170-micron filter located within the DEF pump supply block.

  • DEF Tank Cap48024751

    Example part number, verify fitment by serial number.

Get help to fix this fault by requesting a quote

Browse other New Holland codes