New Holland TMF 125 – TMF (Tractor Multifunction Controller): Aux 1st Raise Coil solenoid shorted to 12 volts.
Issue description
The control module has detected current on the circuit for the Auxiliary 1 (Remote 1) valve's 'extend' or 'raise' solenoid coil when the driver circuit is commanded OFF. This indicates that the circuit is shorted directly to a 12-volt power source, either internally within the solenoid coil or within the wiring harness.
Applies to these machines
6 machines- T6
- T7
- T8
- T9
- TM
- MXM
Check the cause
Disconnect the electrical connector for the Auxiliary 1 (Remote 1) 'Raise/Extend' solenoid coil located at the rear valve block.
Turn the tractor key to the ON position and check the active fault codes.
Observe code changes: If the code changes from TMF 125 to TMF 126, the wiring is fine and the solenoid coil is internally shorted. If the code remains TMF 125, the short to 12 volts is located in the wiring harness.
If the harness is suspect (code remains TMF 125), use a digital multimeter to probe the signal wire at the solenoid connector for 12V while the valve is commanded off. Trace the harness back to the TMF controller looking for chafed wires rubbing against a 12V supply.
Repair steps
Disconnect battery
If the wiring harness is shorted: Disconnect the tractor's negative battery cable.
Inspect wiring harness
Trace the wiring harness from the Aux 1 valve back to the TMF controller. Inspect pinch points, especially where the harness routes near the cab mounts or rear axle.
Remove damaged wire
Cut out the melted or chafed section of the wire.
Splice new wire
Splice in a new section of wire using weather-sealed (heat-shrink) butt connectors.
Protect repaired wire
Wrap the repaired section in a protective wire loom and secure it with zip ties away from moving parts.
Relieve hydraulic pressure
If the solenoid coil is internally shorted: Ensure the tractor is off and hydraulic pressure is relieved.
Disconnect solenoid
Disconnect the electrical connector from the faulty Aux 1 Raise solenoid.
Remove retaining nut
Remove the retaining nut at the end of the valve spool cartridge holding the coil in place.
Replace solenoid coil
Slide the old solenoid coil off the cartridge stem. Slide the new OEM solenoid coil onto the stem.
Reinstall retaining nut
Reinstall and tighten the retaining nut (do not overtighten, as this can warp the cartridge).
Reconnect solenoid
Plug the electrical connector into the new coil.
Test operation
Turn the tractor on, clear the inactive fault codes from the TMF module, and test the Remote 1 valve for proper operation.
Parts you might need
(2)Auxiliary Valve Solenoid Coil (12V DC)
84537085Solenoid Valve 12V DC, 7.3 Ohm. Used on modern New Holland T7 and T8 series electro-hydraulic remote valves.
Valve Solenoid Assembly
48055635Alternative/Assembly OEM Part Number
Get help to fix this fault by requesting a quote