New Holland TMF 127 – TMF: Aux 2nd Lower Coil solenoid shorted to 12 volts
Issue description
The system is sensing electrical current when the auxiliary #2 driver is commanded off, indicating a short circuit to a 12-volt power source on the retract/lower coil circuit of the second auxiliary hydraulic valve.
Applies to these machines
15 machines- T6 series
- T7 series
- T8 series
- T9 series
- T8000 series
- T8010
- T8020
- T8030
- T8040
- T8050
- TG series
- TG215
- TG275
- MXM series
- TM series
Check the cause
Verify the condition by checking if current is still being sensed by the controller when the Aux #2 driver is turned off.
Inspect the wiring harness leading to the Aux 2 lower/retract solenoid for any chafing, melted insulation, or exposed wires that could be causing a short to a 12-volt source.
Test the solenoid coil itself with a multimeter to determine if the internal coil has shorted out.
Repair steps
Locate valve
Locate the Auxiliary Valve #2 on the tractor's rear hydraulic remote stack.
Disconnect connector
Disconnect the electrical connector from the Aux 2 lower/retract coil solenoid.
Test voltage
With the tractor powered on but the Aux 2 driver commanded off, use a multimeter to test the wiring harness for voltage.
Repair wiring
If 12 volts are present on the harness side when it should be off, trace the wiring harness back to the TMF controller and repair the short to 12 volts in the wiring.
Replace solenoid
If the wiring harness tests fine (no voltage present when commanded off), the fault is an internal short within the solenoid itself. Remove and replace the Aux 2 lower coil solenoid.
Test operation
Reconnect the harness, clear the fault codes, and test the auxiliary valve operation to ensure the code does not return.
Parts you might need
(5)New Holland Hydraulic Solenoid Valve
87446004New Holland Solenoid
84128131Deluxe Solenoid Hydraulic Valve
47137763Fits TN series
TMF Controller Module
51563039Tractor Multifunction Controller, 5 Connector
TMF Controller Module
87617964Tractor Multifunction Controller, 5 Connector
Get help to fix this fault by requesting a quote