New Holland TMF 141 – TMF Controller: Aux 5th Raise Coil solenoid shorted to 12 volts
Issue description
The controller is sensing electrical current on the circuit when the Auxiliary #5 driver is commanded OFF. This indicates that the extend/raise coil for the 5th auxiliary remote valve is experiencing a short circuit directly to a 12-volt power source.
Applies to these machines
13 machines- TG210
- TG230
- TG245
- TG255
- TG275
- TG285
- TG305
- T8010
- T8020
- T8030
- T8040
- T8050
- T9000 Series
Check the cause
Inspect the wiring harness running from the TMF Controller to the Aux 5 remote valve stack for chafed, pinched, or melted wires that could be bridging the solenoid control wire to a constant 12-volt power wire.
Disconnect the electrical connector at the Aux 5 Raise/Extend solenoid and test the solenoid coil for an internal short circuit.
With the solenoid disconnected, turn the key on and check if the 12-volt short is still present on the harness side to determine if the short is in the harness or the TMF controller's internal driver has failed.
Repair steps
Disconnect Power
Turn off the tractor and disconnect the battery to prevent further electrical damage during the repair.
Access the Remote Valve Stack
Locate the electro-hydraulic remote valve stack at the rear of the tractor and identify the 5th auxiliary valve section.
Repair Wiring (If Applicable)
If the diagnostic checks revealed a short to 12V in the wiring harness, splice and repair the damaged section of the wire, or replace the affected harness segment. Secure the harness with zip ties to prevent future rubbing.
Replace the Solenoid (If Applicable)
If the Aux 5 Raise coil was internally shorted, remove the retaining nut/hardware holding the solenoid coil to the proportional valve cartridge. Slide the old coil off and install the new replacement solenoid.
Reassemble and Clear Codes
Reconnect the solenoid electrical connector. Reconnect the battery. Use a diagnostic tool or the tractor's instrumentation display to clear the TMF 141 fault code.
Test Operation
Start the tractor and operate the 5th auxiliary remote valve in the raise/extend direction to verify the short has been resolved and the code does not return.
Parts you might need
(3)Remote Valve Solenoid (Proportional Valve)
278506A1Fits New Holland TG/T8000 and Case IH equivalents
TMF Controller (Tractor Multi-Function Controller)
87393065Only required if the internal driver inside the module has permanently shorted and failed
TMF Controller (Tractor Multi-Function Controller)
51563039Only required if the internal driver inside the module has permanently shorted and failed
Get help to fix this fault by requesting a quote