TMF 150

New Holland TMF 150 – TMF (Tractor Multi-Function) Controller: Implement feedback #2 out of range Low

Issue description

This fault code indicates that the feedback sensor for implement #2 (typically a position sensor or potentiometer associated with the rear hitch or an electro-hydraulic remote valve) is returning a voltage signal that is below the acceptable minimum threshold. This condition usually points to an open circuit, a short to ground in the sensor wiring, or an internal failure of the sensor itself.

Applies to these machines

  • TG210
  • TG215
  • TG230
  • TG245
  • TG255
  • TG275
  • TG285
  • TG305
  • T8010
  • T8020
  • T8030
  • T8040
  • T8050
  • Magnum
  • MX/TG Series
  • MX210
  • MX305

Check the cause

  1. Visual Inspection: Inspect the wiring harness running from the TMF controller to the implement #2 feedback sensor (located near the rear hitch or remote valves). Look for chafed wires, pinched harnesses, or melted insulation.

  2. Connector Check: Disconnect the sensor and check for corrosion, moisture, or bent pins inside the connector.

  3. Voltage Test: Turn the key to the ON position and check for a 5V reference supply at the sensor connector. If the 5V supply is missing, trace the wire back to the TMF controller to check for an open circuit.

  4. Continuity/Short Test: Test the signal wire for continuity back to the TMF controller, and ensure it is not shorted to ground.

Repair steps

  1. Disconnect Power

    Turn off the tractor and disconnect the negative battery cable to prevent electrical spikes.

  2. Repair Wiring

    If the diagnostic checks revealed a short to ground or a broken wire in the harness, repair the damaged section using weather-sealed heat shrink connectors, or replace the affected harness section.

  3. Replace the Sensor

    If the wiring and 5V reference are intact, the sensor itself has failed. Remove the mounting hardware securing the implement #2 feedback sensor, remove the old sensor, and install the replacement.

  4. Reassemble and Power Up

    Reconnect the sensor harness and the battery.

  5. Clear Codes and Calibrate

    Use a diagnostic tool to clear the TMF 150 fault code. You must then perform a hitch/implement calibration procedure (often done via the tractor's display monitor or a dealer laptop) so the TMF controller can learn the new sensor's minimum and maximum voltage ranges.

Parts you might need

(4)
  • Implement Feedback Sensor / Hitch Position Sensor

    The exact OEM part number for the sensor depends heavily on the specific hitch or remote valve configuration of the tractor. Consult a dealer parts catalog with your specific VIN/Serial Number.

  • Tractor Multifunction Controller (TMF / ECU)

    51563039

    Only replace the TMF controller if the sensor and wiring have been completely ruled out and the controller is failing to output the 5V reference or read the return signal.

  • Tractor Multifunction Controller (TMF / ECU)

    87617964

    Only replace the TMF controller if the sensor and wiring have been completely ruled out and the controller is failing to output the 5V reference or read the return signal.

  • Tractor Multifunction Controller (TMF / ECU) (Remanufactured)

    87617964R

    Only replace the TMF controller if the sensor and wiring have been completely ruled out and the controller is failing to output the 5V reference or read the return signal.

Get help to fix this fault by requesting a quote