New Holland TMF 169 – Armrest Controller: PTO ON/OFF switch has failed in the Armrest Controller
Issue description
The system detects that both the PTO ON and OFF switches are simultaneously registering as "off," which means that one of the PTO switches is shorted to ground.
Applies to these machines
8 machines- New Holland T6
- New Holland T7
- New Holland T8
- New Holland T9
- New Holland T6000
- New Holland T7000
- New Holland TM
- New Holland MXM
Check the cause
Inspect the wiring harness running from the PTO switch inside the armrest down to the Armrest Controller for pinched wires, chafing, or exposed copper touching the chassis/ground
Disconnect the PTO switch and use a multimeter to test for internal continuity, verifying if the switch is internally shorted to ground when toggled
Test the specific pins on the Armrest Controller that receive the PTO switch signal to ensure the controller itself isn't internally shorted
Repair steps
Power Down
Turn off the tractor, remove the key, and disconnect the negative battery terminal to prevent electrical spikes.
Access the Switch
Carefully remove the trim panels or retaining screws on the armrest control console to access the underside of the PTO switch.
Disconnect
Unplug the electrical connector from the faulty PTO switch.
Remove and Replace
Depress the retaining tabs (or remove the mounting screws) holding the PTO switch in the armrest bezel and pull it out. Insert the new OEM PTO switch until it clicks into place.
Reassemble
Reconnect the wiring harness to the new switch. Reinstall the armrest console trim.
Test
Reconnect the battery, turn the key on, and clear the stored TMF 169 fault code. Engage and disengage the PTO to verify the repair.
Parts you might need
(2)PTO Switch Assembly (Armrest)
87494204Alternative/Superseded: 87711522. Fits New Holland T6, T7, T8, T9, T6000, T7000 series, and Case IH Puma series.
Arm Rest Control Switch (Seat Height/PTO variants)
87347940Alternative: 87308605. Fits New Holland TM, T7, T7000, and Case IH MXM, Puma.
Get help to fix this fault by requesting a quote