New Holland TMF 172 – TMF: PTO Solenoid Circuit is failed shorted to 12 Volts when PTO is in the off state.

Issue description

The system has detected that the Power Take-Off (PTO) solenoid circuit is receiving 12 volts (B+) even though the PTO switch and system are commanded to the "OFF" state. This indicates an electrical short to power, which can cause the PTO to engage unexpectedly or prevent the system from operating safely.

Applies to these machines

  • T6
  • T7
  • T8
  • T9
  • TM
  • TS
  • CR
  • CX
  • CR9090
  • CX8080
  • CX8090
  • Magnum
  • 235-340 Series 4
  • Puma
  • Maxxum

Check the cause

  1. Test the resistance of the PTO solenoid coil at the PTO controller connector to see if the coil has failed internally (resistance too low).

  2. Inspect the wiring circuit between the TMF controller and the PTO solenoid for a short to a +12V power source.

  3. Determine if the TMF controller has an internal failure (such as an internal relay that is stuck in the 'ON' position).

Repair steps

  1. Access the Components

    Turn off the tractor and locate the rear PTO solenoid and the TMF central controller (often located under the rear cab cover or right-hand console, depending on the model).

  2. Disconnect and Inspect

    Disconnect the rear PTO solenoid connector and the inline harness connectors. Inspect the pins for corrosion, moisture, or melted plastic.

  3. Test the Solenoid

    Using a digital multi-meter, measure the resistance across the PTO solenoid pins. If the resistance is out of specification (shorted/too low), the solenoid itself is faulty and must be replaced.

  4. Test the Wiring Harness

    With the solenoid and controller disconnected, test the PTO signal wire for continuity to any 12-volt power source. If you read voltage or continuity to power, the wiring harness is chafed and shorting to a live wire. Repair the damaged section of the harness or replace the harness assembly.

  5. Test the Controller

    If the solenoid resistance is correct and the wiring harness is not shorted, the fault is likely a stuck internal relay inside the TMF controller. The controller will need to be replaced and reprogrammed by a dealer.

  6. Clear and Verify

    Once the faulty component is repaired or replaced, clear the TMF 172 error code via the diagnostic menu and test the PTO system for normal operation.

Parts you might need

(7)
  • PTO Solenoid / Transmission Solenoid Valve

    47658159

    New Holland AG updated part. Fits a wide variety of New Holland T-series (T4, T5, T6, T7, T8) and TM series tractors.

  • PTO Solenoid / Transmission Solenoid Valve

    87739558

    Fits a wide variety of New Holland T-series (T4, T5, T6, T7, T8) and TM series tractors.

  • PTO Solenoid / Transmission Solenoid Valve

    5196873

    Fits a wide variety of New Holland T-series (T4, T5, T6, T7, T8) and TM series tractors.

  • PTO Solenoid / Transmission Solenoid Valve

    48055262

    Fits a wide variety of New Holland T-series (T4, T5, T6, T7, T8) and TM series tractors.

  • PTO Solenoid / Transmission Solenoid Valve

    87577678

    Fits a wide variety of New Holland T-series (T4, T5, T6, T7, T8) and TM series tractors.

  • PTO Solenoid Wire Harness Assembly

    82013103

    Primarily for older series (TS, 40 series) but check specific model catalogs for modern T-series harness part numbers.

  • TMF Controller (Central Controller / XCM)

    Varies heavily by exact tractor model, year, and transmission type. Must be sourced via dealer using the machine's PIN/Serial Number.

Get help to fix this fault by requesting a quote

Browse other New Holland codes