TMF 179

New Holland TMF 179 – PTO Controller: The PTO is receiving no frequency from the Shaft Size Sensor on a two speed PTO.

Issue description

The tractor's PTO is configured as a two-speed system, but when the PTO is switched on, the controller fails to detect any frequency signal from the shaft size sensor.

Applies to these machines

  • T4 Series
  • T5 Series
  • T6 Series
  • T7 Series
  • T8 Series
  • T9 Series
  • MXM/TM Series
  • MX Magnum
  • TG Series
  • Puma
  • Optum

Check the cause

  1. Verify Configuration: Ensure the tractor is actually equipped with and configured for a two-speed PTO.

  2. Check for Swapped Connectors: Verify that the wiring connectors for the PTO Shaft Speed Sensor and the PTO Shaft Size Sensor have not been accidentally swapped.

  3. Test Sensor Resistance: Disconnect the PTO Shaft Size Sensor and check the resistance across the sensor pins (should be approximately 3,000 ohms).

  4. Check Wiring Continuity: Inspect the wiring harness between the PTO controller and the PTO shaft size sensor for continuity and ensure there is no short to the chassis ground.

Repair steps

  1. Power Down

    Turn off the tractor, remove the key, and ensure the PTO is fully disengaged.

  2. Locate the Sensor

    Locate the PTO Shaft Size Sensor, which is mounted directly at the rear PTO shaft housing (do not confuse it with the PTO Speed Sensor on top of the transmission).

  3. Inspect the Harness

    Disconnect the sensor's electrical connector. Inspect the pins for corrosion, moisture, or pushed-back terminals. Clean with contact cleaner if necessary.

  4. Test the Sensor

    Measure the resistance of the sensor. If it reads open (infinite resistance), shorted, or significantly out of the 3 K ohm range, the sensor has failed internally and must be replaced.

  5. Replace the Sensor

    Remove the retaining bolt securing the sensor to the housing. Pull the faulty sensor straight out. Lubricate the O-ring on the new sensor with clean hydraulic/transmission oil, insert it into the housing, and tighten the retaining bolt.

  6. Repair Wiring

    If the sensor tested good in Step 4, the fault lies in the wiring harness. Trace the wires back to the PTO controller and repair any breaks, chafing, or shorts to ground.

  7. Clear Codes and Test

    Reconnect the harness, power on the tractor, and clear the stored fault codes. Engage the PTO to verify that the TMF 179 code does not return and that the shaft size frequency is now being detected.

Parts you might need

(4)
  • New Holland PTO Speed Sensor

    47767004

    Fits various New Holland and Case IH tractors.

  • New Holland PTO Shaft Speed Sensor

    87564763

    Fits various New Holland and Case IH tractors.

  • New Holland / Case IH Speed Sensor

    4897242

    Common aftermarket replacement target. Fits various New Holland and Case IH tractors.

  • PTO Speed Sensor

    56782

    Specific to T7 / Puma / Optum series.

Get help to fix this fault by requesting a quote

Browse other New Holland codes