TMF 59

New Holland TMF 59 – TMF (Tractor Multi-Function) Controller: Both Draft Pin voltages are not within spec for ‘no load’ condition during calibration

Issue description

During the hitch calibration procedure, the controller is reading a baseline voltage from both the left and right draft pins (load sensors) that falls outside the acceptable programmed parameters for an unloaded state.

Applies to these machines

  • TG210
  • TG230
  • TG255
  • TG285
  • TG305
  • T8010
  • T8020
  • T8030
  • T8040
  • T8050
  • TM120
  • TM130
  • TM140
  • TM155
  • TM175
  • TM190
  • T6 Series
  • T7 Series

Check the cause

  1. Verify 'No Load' State: Ensure there is absolutely no implement attached to the 3-point hitch and that the hitch is completely free to move without binding.

  2. Harness & Connector Inspection: Check the wiring harness and connectors leading to both the left and right draft pins for physical damage, corrosion, or short circuits.

  3. Reference Voltage Check: Check the reference voltage supplied to the draft pins by the TMF controller. Depending on the specific tractor model, this should be a steady 5-volt or 8-volt reference.

  4. Sensor Check: If the wiring and reference voltages are intact, the draft pins themselves have likely failed internally or drifted out of calibration range.

Repair steps

  1. Remove Implements

    Disconnect any implements from the 3-point hitch to ensure a true 'no load' condition.

  2. Repair Wiring

    If diagnostic checks revealed damaged wiring or corroded connectors at the lower link arms, repair or replace the affected harness sections.

  3. Replace Draft Pins

    If the harness is good, replace the faulty draft pin sensors on the lower hitch links.

  4. Recalibrate

    After replacing the sensors or repairing the wiring, you must perform the Hitch Calibration procedure.

  5. Alternative Bypass (Optional)

    If the tractor is used in an application where draft control is never needed (e.g., pulling a feed wagon), aftermarket 'Draft Load Sensing Pin Elimination Kits' can be installed. These plug into the harness to send a fixed 'no load' voltage to the TMF controller, permanently bypassing the sensors and clearing the code.

Parts you might need

(3)
  • Draft Sensor / Draft Control Pin / Load Sensing Pin

    87351611

    Replaces older # 322022A1. Fits TG Series and T8 Series tractors.

  • Draft Sensor / Draft Control Pin / Load Sensing Pin

    47137583

    Replaces older # 87661289. Fits T6, T7, and TM Series tractors.

  • Draft Load Sensing Pin Elimination Kit

    Aftermarket alternative. Available from aftermarket agricultural electrical suppliers like Larsen Lights.

Get help to fix this fault by requesting a quote

Browse other New Holland codes