New Holland TRANS 136 – Transmission Controller (TRANS): Communication lost with the instrumentation controller
Issue description
The CAN Bus communication link between the transmission controller and the instrumentation controller has been interrupted or lost.
Applies to these machines
15 machines- TG210
- TG215
- TG230
- TG245
- TG255
- TG285
- T8030
- T8040
- TJ280-TJ530
- T9010-T9060
- T6010-T6070
- T70 series
- MXM / TM Series
- Magnum 235-340
- MX Magnum
Check the cause
Verify both the transmission controller and the instrumentation controller are powering up and functioning correctly
Inspect the CAN Bus wiring harness that runs between the transmission controller and the instrumentation controller
Look for bad CAN Bus connections, such as corroded pins, loose terminals, or moisture intrusion at the controller harness plugs
Ensure the tractor model configuration is set correctly in the instrumentation controller (ST MODEL parameters)
Repair steps
Access the Controllers
Locate the Transmission Controller and the Instrumentation Controller (ICU2) on your specific tractor model.
Harness Inspection & Repair
Disconnect the wiring harnesses from both controllers. Use a multimeter to check for continuity, shorts to ground, or shorts to power on the CAN Bus lines between the two modules.
Clean Connections
Clean the mating pins and connectors thoroughly. Reconnect the harnesses and ensure they are seated and locked properly.
Test Voltage/Ground
Verify that the instrumentation controller is receiving proper operating voltage (e.g., 8V or 12V depending on the pinout) and has a solid ground.
Replace Faulty Component
If the wiring harness tests perfectly but communication cannot be established, one of the controllers has suffered an internal failure. Replace the faulty controller (usually the Instrumentation Controller if it fails to output reference voltages, or the Transmission Controller if it fails to send/receive data).
Recalibrate/Configure
If a controller is replaced, use the electronic service tool to configure the new controller to the correct tractor model and clear the stored TRANS 136 fault code.
Parts you might need
(5)Instrument Cluster Module / ICU2
84237004RRemanufactured ICU2 Module for select models
Transmission Control ECU / Module
84348127T9 Series / Steiger
Transmission Control ECU / Module
82016740TS Series 24x24
Transmission Control ECU / Module
860274248970 chassis control
CAN Bus / ICU Wire Harness
87314407ICU to ICU2 Wire Harness